United States Nuclear Regulatory Commission - Protecting People and the Environment

Resolution of Generic Safety Issues: NMSS-0011. Spent Fuel Dry Cask Weld Cracks ( NUREG-0933, Main Report with Supplements 1–34 )

DESCRIPTION

In early 1997, the NRC became aware that, on four separate occasions, utilities using the ventilated storage cask (VSC)-24 spent fuel dry cask storage system had experienced cracking while making the cask closure welds. In May 1997, the NRC issued confirmatory action letters (CALs) to the Southern Nuclear Corporation (SNC) and three utilities to document their commitments not to load additional VSC-24 systems until the root cause of the cracking was identified and corrective actions were implemented to prevent recurrence. This issue was identified1709 by NMSS to address the staff concern that the welding problems may exist in other cask designs in use.

CONCLUSION

SNC and the utilities formed an Owners' Group to resolve the welding problems. The staff reviewed the root cause of the welding problems and assessed whether the corrective actions implemented by the VSC-24 Cask Owners' Group adequately resolved the welding problems. The corrective actions, including an improved welding technique and a UT of the weld joint, were approved by the NRC.1722

During certification of the MP-187 dry storage canister, NMSS performed all necessary activities required to assess the generic implications of welding problems for cask designs in use. Guidance related to this issue was expected to be incorporated into a revision of NUREG-1536.1721 Thus, the issue was resolved.1720

Page Last Reviewed/Updated Thursday, March 29, 2012