Part 21 Report - 1997-560
LICENSEE: ABB COMBUSTION ENGINEERING
SITE: ABB COMBUSTION ENGINEERING EN NUMBER:32762
DOCKET: EVENT DATE: 08-14-97
RX TYPE: EVENT TIME: 00:00
VENDORS: NOTIFY DATE: 08-14-97
EMERGENCY CLASS: N/A REGION: 1 STATE: CT TIME: 14:24
OPS OFFICER: BOB STRANSKY
10 CFR SECTION: CCCC 21.21 UNSPECIFIED PARAGRAPH
10 CFR PART 21 REPORT
ENERGY REDISTRIBUTION FACTORS USED IN LARGE-BREAK LOSS OF COOLANT
ACCIDENT ANALYSES DO NOT DIRECTLY REFLECT THE EFFECTS OF
MODERATOR VOIDING. SPECIFICALLY, THE ENERGY REDISTRIBUTION
FACTORS ARE UNDER PREDICTED BY 0.5% TO 1.5%. THIS CORRESPONDS TO
A 20�F TO 60�F INCREASE IN PEAK CLAD TEMPERATURE DURING
LARGE-BREAK LOSS OF COOLANT ACCIDENTS.
THE FOLLOWING UNITS ARE AFFECTED: PALO VERDE UNITS 1, 2, AND 3;
SAN ONOFRE UNITS 2 AND 3; WATERFORD UNIT 3; ARKANSAS NUCLEAR ONE
UNIT 2; CALVERT CLIFFS UNITS 1 AND 2; AND SAINT LUCIE UNIT 2.
Page Last Reviewed/Updated Wednesday, March 24, 2021