U.S. Nuclear Regulatory Commission Operations Center Event Reports For 02/16/2016 - 02/17/2016 ** EVENT NUMBERS ** | Agreement State | Event Number: 51718 | Rep Org: WA OFFICE OF RADIATION PROTECTION Licensee: WASHINGTON STATE UNIVERSITY Region: 4 City: PULLMAN State: WA County: License #: WN-C003-1 Agreement: Y Docket: NRC Notified By: ANINE GRUMBLES HQ OPS Officer: JEFF ROTTON | Notification Date: 02/09/2016 Notification Time: 11:47 [ET] Event Date: 02/04/2016 Event Time: [PST] Last Update Date: 02/09/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): NEIL OKEEFE (R4DO) NMSS_EVENTS_NOTIFIC (EMAI) | Event Text AGREEMENT STATE REPORT - LEAKING NI-63 SEALED SOURCE The following information was provided by the State of Washington via email: "Radiation Safety staff at WSU [Washington State University] discovered a GC ECD [Gas Chromatography - Electron Capture Detector] to be leaking during the semi annual sealed source leak test. The sealed source leak test revealed 0.00686 microCuries of removable contamination. The source was removed from the laboratory where it was stored in a box and immediately transferred to radioactive waste, pending disposal. The ECD had been stored in a box and had not been used for several years. Both the source location and the GC were surveyed to ensure contamination was not present. Survey results were well below regulatory limits." The source manufacturer/model number: Hewlett Packard model 5890A, serial number M2044. The sealed source contains 0.015 Ci of Ni-63. WA Incident Number: WA-16-005 | Agreement State | Event Number: 51719 | Rep Org: PA DEPT OF ENV PROTECTION Licensee: CROZER CHESTER MED CTR Region: 1 City: UPLAND State: PA County: License #: PA-0061 Agreement: Y Docket: NRC Notified By: JOSEPH MELNIC HQ OPS Officer: DANIEL MILLS | Notification Date: 02/09/2016 Notification Time: 12:21 [ET] Event Date: 02/03/2016 Event Time: 13:00 [EST] Last Update Date: 02/09/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): RAY POWELL (R1DO) NMSS_EVENTS_NOTIFIC (EMAI) ANGELA MCINTOSH (NMSS) | Event Text AGREEMENT STATE REPORT - UNPLANNED CONTAMINATION The following was received from Pennsylvania via fax: "The licensee discovered the event on February 4, 2016, and notified the Department [PA Dept of Environmental Protection] after normal business hours on Friday, February 5, 2016. It is reportable per 10 CFR 30.50(b)(1)(i). "A 30 year old female patient was treated with 61.4 milliCuries of Iodine-131(I-131) for thyroid cancer and released, with proper discharge instructions, at noon on 02/03/16. The patient then returned to the emergency room (ER) at the same location at [1300 EST]. The patient did not disclose the previous I-131 treatment to ER staff until later that evening. The ER staff immediately contacted radiation safety personnel at 0100 on 02/04/16. The patient was then segregated and all access to the original room was controlled and posted properly. Surveys were taken and all linens and other potentially contaminated materials were collected for proper storage and decay. A radiation survey performed at 0930 on 02/04/16 estimated the potential maximum radiation exposure to staff to be 3 millirem. "Patient failed to follow the discharge instructions given. "A reactive inspection is planned by the Department. More information will be provided upon receipt." Pennsylvania Event Report ID #: PA160006 | Power Reactor | Event Number: 51738 | Facility: SALEM Region: 1 State: NJ Unit: [ ] [2] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: BILL MUFFLEY HQ OPS Officer: DANIEL MILLS | Notification Date: 02/16/2016 Notification Time: 13:44 [ET] Event Date: 02/16/2016 Event Time: 08:27 [EST] Last Update Date: 02/16/2016 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION | Person (Organization): GLENN DENTEL (R1DO) | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 2 | N | Y | 4 | Startup | 4 | Startup | Event Text AUXILIARY FEEDWATER PUMP AUTO START DUE TO FEED PUMP TRIP "At 0827 [EST], the 21 and 22 Aux Feedwater pumps auto started due to a trip of the running Steam Generator Feed pump (22). The 22 Steam Generator Feed pump tripped while swapping from heating steam to main steam in accordance with normal operating procedures. The cause of the 22 Steam Generator Feed pump trip is being investigated at this time. "The auto start of the Unit 2 Auxiliary Feedwater pumps is being reported in accordance with 10 CFR 50.72(b)(3)(iv)(A), 'Any event or condition that results in valid actuation of any system listed in Technical Basis 11.3.3 except when the actuation results from and is part of a pre-planned sequence during testing or reactor operation.'" The licensee has notified the NRC Resident Inspector and will notify the Lower Alloways Creek Township. | |