| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 09/04/2014 - 09/05/2014 ** EVENT NUMBERS ** | | Agreement State | Event Number: 50408 | Rep Org: ARIZONA RADIATION REGULATORY AGENCY Licensee: WESTERN TECHNOLOGIES, INC Region: 4 City: PHOENIX State: AZ County: License #: AZ 7-080 Agreement: Y Docket: NRC Notified By: SHANNA FARISH HQ OPS Officer: CHARLES TEAL | Notification Date: 08/27/2014 Notification Time: 12:23 [ET] Event Date: 08/25/2014 Event Time: 09:00 [MST] Last Update Date: 08/27/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): GREG PICK (R4DO) FSME EVENTS RESOURCE (EMAI) | Event Text AGREEMENT STATE REPORT - MOISTURE DENSITY GAUGE DAMAGED AT CONSTRUCTION SITE The following from the State of Arizona via email: "At approximately 9:00 AM [MDT] on August 26, 2014, the Agency [State of Arizona] was informed that the licensee had a Troxler Model 3430 portable moisture/density gauge damaged at a construction site. The damage occurred at approximately 9:00 AM on August 25, 2014. The gauge was in use and was run over by construction equipment. The sealed sources were not damaged and were intact. The damaged gauge was leaked tested and will be returned to Troxler for repairs. The gauge, serial number 29852, contains 10 mCi of Cesium-137 and 40 mCi of Am:Be-241. "The Agency continues to investigate the event. "The Governor's Office and U.S. NRC are being notified of this event." Arizona First Notice: 14-019 | | Agreement State | Event Number: 50409 | Rep Org: ARIZONA RADIATION REGULATORY AGENCY Licensee: WESTERN TECHNOLOGIES, INC Region: 4 City: PHOENIX State: AZ County: License #: AZ 7-049 Agreement: Y Docket: NRC Notified By: SHANNA FARISH HQ OPS Officer: CHARLES TEAL | Notification Date: 08/27/2014 Notification Time: 13:44 [ET] Event Date: 08/25/2014 Event Time: 15:30 [MST] Last Update Date: 08/27/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): GREG PICK (R4DO) FSME EVENTS RESOURCE (EMAI) | Event Text AGREEMENT STATE REPORT - AUTOMOTIVE ACCIDENT INVOLVING AN IR-192 CAMERA The following was received from the State of Arizona via email: "At approximately 9:00 AM [MDT] on August 26, 2014, the Agency [State of Arizona] was informed that the licensee had a company truck involved in a rollover accident. The truck was transporting an Iridium-192 gamma camera used for industrial radiography. The camera was not damaged in the accident and was transported by the licensee back to their Phoenix office. The gamma camera was leak tested. The accident occurred at approximately 3:30 PM on August 25, 2014. The Delta 880, Serial Number D9783, radiographic camera contains approximately 100 Ci of Ir-192. "The Agency continues to investigate the event. "The Governor's Office and U.S. NRC are being notified of this event. " Arizona First Notice: 14-020 | | Agreement State | Event Number: 50412 | Rep Org: GEORGIA RADIOACTIVE MATERIAL PGM Licensee: GEORGIA DEPARTMENT OF TRANSPORTATION Region: 1 City: ATLANTA State: GA County: License #: GA50-1 Agreement: Y Docket: NRC Notified By: BARTY SIMONTON HQ OPS Officer: STEVE SANDIN | Notification Date: 08/28/2014 Notification Time: 15:30 [ET] Event Date: 08/28/2014 Event Time: 12:00 [EDT] Last Update Date: 08/28/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): KEVIN MANGAN (R1DO) FSME EVENTS RESOURCE (EMAI) ILTAB (EMAI) | | This material event contains a "Less than Cat 3 " level of radioactive material. | Event Text AGREEMENT STATE REPORT - TROXLER MOISTURE DENSITY GAUGE STOLEN FROM PICKUP TRUCK A Georgia Department of Transportation crew stopped for lunch at 1200 EDT on 08/28/14 at a Sam's Club in McDonough, GA. A Troxler Model 3430, S/N 31643, containing two sources: 10 mCi of Cs-137 and 40 mCi of Am241/Be, was stolen from the unattended vehicle. The Troxler was not properly secured as required. The State of Georgia is conducting an investigation into the incident. The Henry County Police Department is investigating. THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf | | !!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!! | | Non-Agreement State | Event Number: 50420 | Rep Org: NATIONAL INST OF STANDARDS & TECH Licensee: NATIONAL INST OF STANDARDS & TECH Region: 1 City: GAITHERSBURG State: MD County: MONTGOMERY License #: SNM-362 Agreement: Y Docket: NRC Notified By: TOM O'BRIEN HQ OPS Officer: STEVE SANDIN | Notification Date: 08/30/2014 Notification Time: 16:00 [ET] Event Date: 08/29/2014 Event Time: 16:00 [EDT] Last Update Date: 09/04/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: 70.50(b)(1) - UNPLANNED CONTAMINATION | Person (Organization): KEVIN MANGAN (R1DO) KING STABLEIN (NMSS) | Event Text UNPLANNED CONTAMINATION INCIDENT IN THE RESEARCH REACTOR FACILITY At approximately 1600 EDT on 08/29/14, a 60 nanocurie Pu-239 wafer source dropped from its holder during change out following neutron irradiation in building 235 (Research Reactor Test Facility). The wafer struck the floor and cleaved in half. Radiation surveys confirmed alpha contamination of approximately 200 counts per minute. The area was decontaminated, resurveyed and released. The licensee will notify their NMSS PM (Naquin) and the State of Maryland Department of Environment as a courtesy. * * * UPDATE AT 1840 EDT ON 08/30/14 FROM TOM O'BRIEN TO STEVE SANDIN VIA EMAIL * * * "Follow-up to the dropped source (Pu-239 RS# 87-0039(4) on 8/29/14)) at NG-6MAll personnel involved have been evaluated, with the exception of two nasal swipes, on two separate individuals not directly involved with the incident, but near the location, reporting about 0.17 dpm alpha each, all surveys find the personnel to be clear of contamination. It is believed the two 0.17 dpm nasal swipes are statistically not different than zero, follow-up measurements will be done to confirm this. Even if we assume them to be positive, the resulting estimated dose from these measurements would be on the order of 10 mrem. "The NG-6M instrument area has been surveyed and cleared for normal use. All contamination swipe surveys of the floor, tools, furniture and equipment potentially involved in this incident have been found to be clean. With the exception of one alpha instrument survey, all surveys with alpha and beta/gamma survey instruments have found levels less than or equal to background. The one survey where positive indication was found was performed at the source drop location, directly underneath where the source fell. This survey was done after the source was retrieve. Initially measured about 200 cpm alpha contamination and very localized, the spot was carefully deconned and subsequent surveys found to be less than or equal to background. All swipes of this spot were also found to be clean. "The source has been safely retrieved, secured and is locked in our safe in A134. No removable contamination was found on the source containers or during retrieval of the source. Gamma spectrum measurements of the retrieved source, detecting the Am-241 trace nuclide, and correlating this activity by know nuclide ratios find that the Pu-239 activity of the source is within good agreement of the original activity of the source (2190 Bq). While this confirmation has many errors incorporated into it, it is the best measurement we can make at this time, that along with the negative findings of any removable contamination to speak of, and visual inspections of the source, I conclude that to the best of my knowledge, the source material is intact on the broken source substrate pieces, inside the source container. Careful follow-up measurements would need to be performed to confirm this for certain, but based on the info I have at present this is my conclusion." Notified R1DO (Mangan), NMSS EO (Stablein) and NMSS PM (Naquin). * * *RETRACTION PROVIDED FROM TOM O'BRIEN TO JEFF ROTTON AT 1425 EDT ON 09/04/2014 * * * "Upon detailed review of the incident data NIST is requesting retraction of this notification on the basis that 70.50 (b)(1)(i) and (ii) are not applicable to this event and therefore no 24 hour (or other notification) was required. Access to the contaminated area was restricted for less than 24 hours. Additionally, at the time of initial reporting on 8/30/2014, the most conservative annual limit on intake (ALI) was used as the chemical composition was not yet known. As of today, 9/3/2014, we have confirmed that the radioactive material is in the form of PuO2. This additional information indicates that the involved quantity of radioactive material was less than five times the lowest ALI for Pu-239. "Since the initial report of 8/30/2014, there has been no other contamination detected. The nasal-swab measurements were analyzed for a longer time period and have been determined to be less than the minimum detectable activity. "NIST is evaluating the incident for lessons learned and extent of conditions and will advise [NRC] Region I and our [NRC] Project Manager of the outcome. "Licensee also requested that the first sentence of the [original] Event Text be corrected as indicated below as the source was not subjected to neutron irradiation. 'At approximately 1600 EDT on 08/29/14, a 60 nanocurie Pu-239 wafer source (that was going to be used to calibrate an instrument detector) dropped from its holder during transfer in building 235 (Research Reactor Test Facility).'" Notified R1DO (Ferdas), NMSS EO (Smith) and NMSS PM (Naquin). | | Power Reactor | Event Number: 50424 | Facility: PRAIRIE ISLAND Region: 3 State: MN Unit: [1] [ ] [ ] RX Type: [1] W-2-LP,[2] W-2-LP NRC Notified By: STEVE INGALLS HQ OPS Officer: CHARLES TEAL | Notification Date: 09/04/2014 Notification Time: 09:50 [ET] Event Date: 09/04/2014 Event Time: 08:43 [CDT] Last Update Date: 09/04/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): CHRISTINE LIPA (R3DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text 1R-50 SHIELD BUILDING HIGH RANGE VENT GAS RADIATION MONITOR OUT OF SERVICE FOR PLANNED MAINTENANCE "At 0843 CDT on September 4th, 2014, 1R-50 High Range Shield Building Vent Gas Monitor was removed from service for planned maintenance. This monitor provides indication of release of gaseous radioactivity to the environment. There is not a compensatory measure that will allow timely classification of two Emergency Action Levels when out of service: General Emergency Event RG1.1 and Site Area Emergency Event RS1.1. This results in a loss of emergency assessment Capability while 1R-50 is out of service. This is a reportable condition in accordance with 10 CFR 50.72(b)(3)(xiii). "Unit 1 Shield Building ventilation stack is also monitored by radiation monitor 1R-22 that is used for the same purpose in Alert or Unusual Event Emergency classifications. 1R-22 is being monitored and is indicating normal values. There are no radioactive leaks that will impact the Shield Building as evidenced by normal readings on 1R-50 prior to its removal from service. The maintenance is scheduled for ten hours or will continue until the monitor is returned to service. Maintenance will not result in the unplanned release of radioactivity to the environment and will not affect the safe operation of the plant or health and safety of the public. "The licensee has notified the NRC Resident Inspector." | | Power Reactor | Event Number: 50427 | Facility: QUAD CITIES Region: 3 State: IL Unit: [1] [2] [ ] RX Type: [1] GE-3,[2] GE-3 NRC Notified By: MARK BRIDGES HQ OPS Officer: HOWIE CROUCH | Notification Date: 09/05/2014 Notification Time: 00:27 [ET] Event Date: 09/04/2014 Event Time: 19:05 [CDT] Last Update Date: 09/05/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION | Person (Organization): CHRISTINE LIPA (R3DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text CONTROL ROOM EMERGENCY VENTILATION (CREV) SYSTEM INOPERABLE "On September 04, 2014, at 1905 hours [CDT], the Control Room Emergency Ventilation (CREV) system was declared inoperable due to the Air Handling Unit (AHU) tripping upon restoration of Control Room Ventilation following testing of Reactor Building Ventilation instrumentation. Troubleshooting is in progress at this time. "Technical Specification 3.7.4, Condition A, was entered which requires the CREV system to be restored to an operable status in seven (7) days. Additionally, Technical Specification 3.7.5, Condition A, was entered which requires CREV AC to be restored to an operable status in 30 days. "This notification is being made in accordance with 10CFR50.72(b)(3)(v)(D), '[any] event or condition that could have prevented fulfillment of a safety function,' because the CREV system is a single train system required to mitigate the consequences of an accident." The licensee has notified the NRC Resident Inspector. | |