Event Notification Report for June 3, 2014
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 06/02/2014 - 06/03/2014 ** EVENT NUMBERS ** | | Agreement State | Event Number: 50135 | Rep Org: NE DIV OF RADIOACTIVE MATERIALS Licensee: NEBRASKA METHODIST HOSPITAL Region: 4 City: LINCOLN State: NE County: License #: 01-07-02 Agreement: Y Docket: NRC Notified By: HOWARD SHUMAN HQ OPS Officer: DANIEL MILLS | Notification Date: 05/23/2014 Notification Time: 16:05 [ET] Event Date: 05/22/2014 Event Time: [CDT] Last Update Date: 05/23/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): HEATHER GEPFORD (R4DO) FSME EVENTS RESOURCE (EMAI) | Event Text AGREEMENT STATE REPORT - PATIENT OVEREXPOSURE DUE TO MISCALCULATION The following was received from the State of Nebraska via fax: "At 1430 CDT, the RSO from Nebraska Methodist Hospital called to report a possible overexposure to a patient who had received a prostate treatment of implanted lodine-125 seeds. The RSO, who was also the Medical Physicist on the case, stated that he had mistakenly used the millicurie value for the air kerma value. The treatment dose was intended to be 145 Gray (14,500 rad) but the implant dose was calculated to be 178 Gray (17,800 rad) so the dose differentiated by 27 percent. It is unknown if the target organ (rectum) will exceed 50 rem." Nebraska Item Number: NE140004 A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. | | Agreement State | Event Number: 50137 | Rep Org: ARIZONA RADIATION REGULATORY AGENCY Licensee: ST JOSEPHS HOSPITAL AND MEDICAL CENTER Region: 4 City: PHOENIX State: AZ County: License #: 07-024 Agreement: Y Docket: NRC Notified By: BRIAN GORETZKI HQ OPS Officer: CHARLES TEAL | Notification Date: 05/23/2014 Notification Time: 17:19 [ET] Event Date: 04/04/2014 Event Time: [MST] Last Update Date: 05/23/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): HEATHER GEPFORD (R4DO) FSME EVENTS RESOURCE (E-MA) | Event Text AGREEMENT STATE REPORT - PATIENT RECEIVED LESS THAN PRESCRIBED DOSE The following was received from the State of Arizona via email: "On May 22, 2014, the Agency was notified of a medical event that occurred on April 4, 2014 involving Y-90 labeled SIR Spheres. "On April 4, 2014, an adult liver tumor patient was treated with an injection of SIR Spheres. The patient was prescribed 59.4 Gy to the liver, but instead, the actual dose to the liver was approximately 39 Gy. It was determined that the error occurred in the step of transferring the dose from the delivery vial to the dosing vial. The step of drawing up the sterile fluid was inadvertently omitted by the nuclear medicine technologist working alone which led to much less than the expected activity/sphere being transferred to the dosing vial. Only after the completion of the procedure was the large amount of residual activity detected and noted. The physicians noted that physiologic factors can affect the amount of spheres reaching the tumor so the discrepancy of the dose delivered apparently was not alarming or significant to them. The RSO discovered the medical event during a records review and recognized that the patient only received 63% of the prescribed dose." Arizona First Notice Number: 14-013 | | Agreement State | Event Number: 50139 | Rep Org: FLORIDA BUREAU OF RADIATION CONTROL Licensee: CORRADINO GROUP Region: 1 City: MIAMI State: FL County: License #: 2770-1 Agreement: Y Docket: NRC Notified By: DAVID PIESKI HQ OPS Officer: DANIEL MILLS | Notification Date: 05/24/2014 Notification Time: 18:28 [ET] Event Date: 05/24/2014 Event Time: [EDT] Last Update Date: 05/24/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): HAROLD GRAY (R1DO) FSME EVENTS RESOURCE (E-MA) | | This material event contains a "Less than Cat 3 " level of radioactive material. | Event Text AGREEMENT STATE REPORT - STOLEN TROXLER MOISTURE DENSITY GAUGE The following was received from the State of Florida: A Troxler moisture density gauge, Model 3430 (Serial #39376), was stolen from a locked trailer located at the 36th Street Bridge Project. Additional information will be provided when it is available. Florida Event Number: FL14-045 THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf | | Power Reactor | Event Number: 50163 | Facility: VOGTLE Region: 2 State: GA Unit: [3] [4] [ ] RX Type: [3] W-AP1000,[4] W-AP1000 NRC Notified By: MICHAEL YOX HQ OPS Officer: CHARLES TEAL | Notification Date: 06/02/2014 Notification Time: 16:47 [ET] Event Date: 06/02/2014 Event Time: 07:52 [EDT] Last Update Date: 06/02/2014 | Emergency Class: NON EMERGENCY 10 CFR Section: 26.719 - FITNESS FOR DUTY | Person (Organization): EUGENE GUTHRIE (R2DO) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 3 | N | N | 0 | Under Construction | 0 | Under Construction | | 4 | N | N | 0 | Under Construction | 0 | Under Construction | Event Text NON-LICENSED CONTRACT EMPLOYEE SUPERVISOR IN VIOLATION OF FITNESS FOR DUTY POLICY A non-licensed contract employee supervisor had a confirmed positive result for a controlled substance. The employee's access to the plant has been terminated. The licensee has notified the NRC Senior Resident Inspector. | |
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021