U.S. Nuclear Regulatory Commission Operations Center Event Reports For 09/04/2008 - 09/05/2008 ** EVENT NUMBERS ** | Power Reactor | Event Number: 44454 | Facility: WATERFORD Region: 4 State: LA Unit: [3] [ ] [ ] RX Type: [3] CE NRC Notified By: JERRY GRUBB HQ OPS Officer: VINCE KLCO | Notification Date: 09/01/2008 Notification Time: 00:16 [ET] Event Date: 08/31/2008 Event Time: 23:00 [CDT] Last Update Date: 09/04/2008 | Emergency Class: UNUSUAL EVENT 10 CFR Section: 50.72(a) (1) (i) - EMERGENCY DECLARED | Person (Organization): VIVIAN CAMPBELL (R4) BRIAN McDERMOTT (IRD) MIKE CHEOK (NRR) ERIC LEEDS (NRR) ELMO COLLINS (R4) | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 3 | N | N | 0 | Hot Standby | 0 | Hot Standby | Event Text NOTIFICATION OF UNUSUAL EVENT DUE TO HURRICANE WARNING ONSITE Site declared a notification of unusual event under HU6/ EAL 7. The site is predicted to experience hurricane force winds from Gustav. As a conservative measure, the plant shutdown was completed at 2232 CDT. The licensee has notified the NRC Resident Inspector, state and local emergency management agencies. Notified DHS (Hill) and FEMA (Blankenship). * * * UPDATE AT 0126 ON 9/4/2008 FROM JERRY GRUBB TO MARK ABRAMOVITZ * * * The site has exited the Notification of Unusual Event (NUE) at 0021 CDT because 1) grid stability has been restored, 2) HU6/EAL 7 is no longer applicable (Hurricane Gustav is no longer affecting the site), and 3) the NUE for leakage greater than 25 gpm (SU7/EAL 2) is no longer applicable (entered at 0726 on 9/1/2008 and terminated at 0729 on 9/1/2008). The reactor is in mode-4 (Hot Shutdown). Notified the R4DO (Jones), NRR (Blount), IRD (Gott), DHS (Dub), and FEMA (Casto). | Power Reactor | Event Number: 44463 | Facility: BROWNS FERRY Region: 2 State: AL Unit: [1] [ ] [ ] RX Type: [1] GE-4,[2] GE-4,[3] GE-4 NRC Notified By: RICKY GIVINS HQ OPS Officer: PETE SNYDER | Notification Date: 09/04/2008 Notification Time: 05:04 [ET] Event Date: 09/03/2008 Event Time: 23:43 [CDT] Last Update Date: 09/04/2008 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL | Person (Organization): REBECCA NEASE (R2) | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text FAILURE OF DAMPERS TO AUTO CLOSE "Due to RPS A Circuit Protector surveillance testing, a transfer of 'A' Reactor Protection System from alternate power supply back to the 1A RPS MG-set was required. An expected group 6 containment isolation signal was received during the power transfer. Upon review of plant status to ensure systems responded as expected, it was determined that reactor ventilation zone exhaust dampers 1-DMP-64-42 and 1-DMP-64-43 (Inboard and Outboard Reactor Zone Exhaust Dampers) failed to auto-close. Isolation of these dampers is a required safety function. "The dampers were administratively closed and deactivated in accordance with plant technical specification 3.6.4.2 action B. At the time of this report the cause for failure to auto close has not been determined." The licensee notified the NRC Resident Inspector. | |