Event Notification Report for April 28, 2004
| U.S. Nuclear Regulatory Commission Operations Center Event Reports For 04/27/2004 - 04/28/2004 ** EVENT NUMBERS ** | | Other Nuclear Material | Event Number: 40693 | Rep Org: BAXTER HEALTH CARE Licensee: BAXTER HEALTH CARE Region: 1 City: AIBONITO State: PR County: License #: 52-21175-01 Agreement: N Docket: NRC Notified By: ANGEL ALICEA HQ OPS Officer: STEVE SANDIN | Notification Date: 04/21/2004 Notification Time: 16:54 [ET] Event Date: 04/21/2004 Event Time: 12:00 [EDT] Last Update Date: 04/27/2004 | Emergency Class: NON EMERGENCY 10 CFR Section: 36.83(a)(1) - UNSHIELD STUCK SOURCE 20.2202(b)(1) - PERS OVEREXPOSURE/TEDE >= 5 REM | Person (Organization): DAVID SILK (R1) TOM DECKER (R2) CHARLIE MILLER (NMSS) JOSEPH GIITTER (NMSS) | Event Text IRRADIATOR SOURCE RACK JAMMED IN THE UP POSITION At 1200 EDT operators were lowering a source rack when it jammed due to a maintenance ladder. The licensee entered their emergency procedure and contacted the manufacturer, i.e., MDS Nordion, for assistance. MDS Nordion is expected onsite at 1040 EDT tomorrow 4/22 to help the licensee develop a recovery plan. The stuck source rack contains approximately 2,030 curies of Co-60. The maze is closed restricting personnel access. There were no personnel exposures associated with this occurrence. A conference call with the Baxter Plant Manager and NRC staff was established to discuss the details of this report. * * * UPDATE ON 04/24/04 @ 1424 BY ANGEL ALICEA TO CHAUNCEY GOULD * * * The licensee reported that at 2000 on 04/23/04 the source was placed in the shielded position submerged in 25 ft of water in the pool. They are terminating this event. Notified Tom Decker, George Pangburn, Frank Costello, Cathy Modes, and Betsey Ullrich * * * UPDATE ON 4/27/04 @ 1129 EDT FROM A. ALICEA TO HOWIE CROUCH * * * The licensee reported that a re-enactment of the event indicates that two plant employees may have been over-exposed during the initial event. The licensee is conservatively reporting this update under 10 CFR 20.2202 (b)(1) since the exposure value is unknown but believed to be less than 5 rem. Personnel dosimetry is being analyzed and the calculations are being verified by the contractor at the site. The licensee will update this event when the exposure data is known. The licensee has informed the on site Regional Materials Inspector (Diaz). Notified NMSS (Fred Brown) and R1DO (Richard Barkley). | | Power Reactor | Event Number: 40706 | Facility: MCGUIRE Region: 2 State: NC Unit: [1] [2] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: JOHN JENKINS HQ OPS Officer: HOWIE CROUCH | Notification Date: 04/27/2004 Notification Time: 09:21 [ET] Event Date: 04/26/2004 Event Time: 09:30 [EDT] Last Update Date: 04/27/2004 | Emergency Class: NON EMERGENCY 10 CFR Section: 26.73 - FITNESS FOR DUTY | Person (Organization): CAUDLE JULIAN (R2) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text NON-LICENSED EMPLOYEE TESTED POSITIVE FOR CONTROLLED SUBSTANCE A non-licensed employee was determined to be under the influence of an illegal drug during a random urinalysis. The employee's access to the plant has been terminated. Contact the Headquarters Operations Officer for additional details. The licensee notified the NRC Resident Inspector. * * * UPDATE ON 4/27/0 JENKINS TO GOULD * * * Contact the Headquarters Operations Officer for details of update. Notified the Reg 2DO (Ernstes) of update. | | Hospital | Event Number: 40707 | Rep Org: US DEPT OF VETERANS AFFAIRS Licensee: VA MEDICAL CENTER Region: 1 City: BIRMINGHAM State: AL County: License #: 03-23853-01VA Agreement: Y Docket: NRC Notified By: MICHAEL SIMMONS HQ OPS Officer: ARLON COSTA | Notification Date: 04/27/2004 Notification Time: 13:20 [ET] Event Date: 04/20/2004 Event Time: [CDT] Last Update Date: 04/27/2004 | Emergency Class: NON EMERGENCY 10 CFR Section: 35.3047(a) - EMBRYO/FETUS DOSE > 50 mSv | Person (Organization): RICHARD BARKLEY (R1) BRUCE BURGESS (R3) FRED BROWN (NMSS) | Event Text DOSE TO AN EMBRYO/FETUS On April 20, 2004, a female patient was administered 6 microcuries of I-131 sodium iodide orally and on April 21, 2004, 12 millicuries of Tc-99m (Tc04). An investigation was undertaken after it was determined that the patient was pregnant. The duration of gestation was estimated as 10 weeks +/- 1 week. The dose to the embryo/fetus occurred on April 20-21, 2004, and it was discovered on April 26, 2004. Outside experts estimated that, if the thyroid were functioning, the fetus received a dose of 6.6 rem, and if the thyroid were not functioning, a dose of 0.5 to 1 rem. The permittee has implemented initial corrective actions to prevent a recurrence of the circumstances that resulted in the dose to the embryo/fetus. The permittee is aware of the requirements for notifying the patient and the referring physician. The Department of Veterans Affairs will evaluate the circumstances related to this incident and will submit a written report to NRC, Region III, within 15 days. | | Power Reactor | Event Number: 40709 | Facility: MAINE YANKEE Region: 1 State: ME Unit: [1] [ ] [ ] RX Type: [1] CE NRC Notified By: DOUGLAS KINNEY HQ OPS Officer: ARLON COSTA | Notification Date: 04/27/2004 Notification Time: 18:50 [ET] Event Date: 04/27/2004 Event Time: 17:14 [EDT] Last Update Date: 04/27/2004 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): RICHARD BARKLEY (R1) | | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | | 1 | N | N | 0 | Decommissioned | 0 | Decommissioned | Event Text LOSS OF COMMUNICATION CAPABILITY THROUGH ENS LINE The licensee was notified by the phone communications provider of a loss of all communications that affected the licensee's Emergency Notification System (ENS) line. The licensee has provided the NRC Operations Center with a back up cell phone. The ENS capability is expected to be restored by 23:00 tonight and after restoration of the phone lines, the licensee will verify ENS functionality. It is believed that the loss of communications was due to maintenance work being performed by the provider on the fiber optics lines. The NRC Resident Inspector was notified by the licensee via voice mail phone message. * * * UPDATE ON 04/27/04 AT 20:24 EDT FROM D. KENNEY TO A. COSTA * * * The ENS line has been restored at 19:33 on 04/27/04. Communications with the US NRC Operations Center was tested satisfactorily. The NRC Resident Inspector will be notified by the licensee via voice mail phone message. Notified the R1DO (Barkley). | |
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021