Event Notification Report for April 15, 1999

… NUCLEAR REGION: 4 |NOTIFICATION DATE: 04/12/1999| | UNIT: [1] [2] [] STATE: AR |NOTIFICATION TIME: 16:59[EDT]| | … VALVE MOVED TO THE | | INTERMEDIATE POSITION AND STOPPED. STATION OPERATORS VERIFIED THAT THE | | VALVE WAS NOT CLOSED … | FACILITY: BRAIDWOOD REGION: 3 |NOTIFICATION DATE: 04/14/1999| | UNIT: …

Event Notification Report for May 10, 2016

… Power Reactor Event Number: 51912 Facility: BRAIDWOOD Region: 3 State: IL Unit: [1] [2] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC … "At approximately 1420 CDT on 5/9/2016, the Braidwood Station Main Control Room was notified by Exelon Corporate …

Information Notice No. 84-83: Various Battery Problems

… 84-83: Various Battery Problems … SSINS No.: 6835 IN 84-83 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF … chargers. Solvent Induced Case Cracking: At the Byron and Braidwood stations in April 1984, 55 instances of battery case …

ACRS 2015 Letter Reports

… License Application for William States Lee III Nuclear Station, Units 1 And 2 01/22/16 11/17/2015 ACRS Assessment of the … Renewal Application for Byron Station Units 1 and 2 and Braidwood Station Units 1 and 2 10/23/15 09/15/2015 Draft …

Morning Report for Macrh 13, 2000

… DOCUMENT: EN 36708 REVIEWER: REXB, E. Goodwin The Nine Mile Unit 2 licensee reported nonconservative calculations for … Dockets: 50-454,50-455 PWR/W-4-LP,PWR/W-4-LP Subject: Byron Station Management Changes Discussion: On March 10, 2000, … Station Operations Manager. Dave Hoots was previously the Braidwood Station Shift Operations Supervisor. All personnel …

Event Notification Report for April 20, 2018

… 53349 Non-Agreement State Event Number: 53325 Rep Org: UNITED STATES NAVY Licensee: UNITED STATES NAVY Region: 1 … Power Reactor Event Number: 53347 Facility: BRAIDWOOD Region: 3 State: IL Unit: [1] [ ] [ ] RX Type: [1] … Undervoltage (UV) Relay occurred. At the time, Braidwood Station Unit 1 was performing a pre-planned Bus 141

Interim Criteria for Shift Staffing (Generic Letter 80-72)

… for Shift Staffing (Generic Letter 80-72) … GL80072 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON. D.C. … stated below and the required staffing levels for selected station configurations and various plant operating modes are … OL REVIEW 1. Farley 2 5 50-364 2. Byron 1/2 50-454, 455 3. Braidwood 1/2 50-456/457 4. LaSalle 1/2 50-373, 374 5. …

ACRS 1985 Letter Reports

… 01/15/1985 Diesel-Generator Failures At North Anna Power Station, Unit 2 01/15/1985 ACRS Report On The Use Of The … High Level Waste Repository 02/11/1985 ACRS Report On The Braidwood Station, Units 1 and 2 02/11/1985 ACRS Comments On …