The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Knowledge and Abilities Catalog for Nuclear Power Plant Operators: Pressurized Water Reactors (NUREG-1122, Revision 2, Supplement 1)

On this page:

Download complete document

Publication Information

Manuscript Completed: September 2007
Date Published: October 2007

Division of Inspection and Regional Support
Office of Nuclear Reactor Regulation
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice

Abstract

The Knowledge and Abilities Catalog for Nuclear Power Plant Operators: Pressurized-Water Reactors (PWRs) (NUREG-1122, Revision 2, Supplement 1) provides the basis for the development of content-valid licensing examinations for reactor operators (ROs) and senior reactor operators (SROs). The examinations developed using the PWR Catalog along with the Operator Licensing Examination Standards for Power Reactors (NUREG-1021, Rev. 9, Supplement 1) will sample the topics listed under Title 10, Code of Federal Regulations, Part 55 (10 CFR 55).

The PWR Catalog contains approximately 5,100 knowledge and ability (K/A) statements for ROs and SROs at PWRs. The catalog is organized into six major sections: Catalog Organization, Generic Knowledge and Ability Statements, Plant Systems, Emergency and Abnormal Plant Evolutions, Components and Theory.

Revision 1 to the PWR Catalog modified the form and content of the original catalog. The K/As were linked to their applicable 10 CFR 55 item numbers. SRO level K/As were identified by 10 CFR 55.43 item numbers. The plant-wide generic and system generic K/As were combined in one section. Systems were organized into nine safety functions and the emergency and abnormal evolutions were reorganized and expanded.

Revision 2 incorporated corrections to the Rev. 1 catalog that were identified during a pilot testing program associated with revision of 10 CFR 55 and implementation of NUREG-1021, Interim Rev. 8, "Operator Licensing Examination Standards for Power Reactors." Corrections to the catalog included:

  1. addition of K/As that had been omitted in Rev. 1 (approximately 70).

  2. deletion of duplicate K/As (approximately 15).

  3. correction of importance values of consolidated K/As to reflect highest previously assigned values (approximately 75).

  4. correction of typographical errors.

  5. addition of importance value modifiers that had been omitted in Rev. 1 (approximately 225).

Revision 2, Supplement 1, includes the following changes:

  1. total replacement of Section 2, "Generic Knowledges and Abilities."

  2. inclusion of one additional Abnormal Plant Evolution (APE), 077, "Generator Voltage and Electric Grid Disturbances," in Section 4.2, "Generic Abnormal Plant Evolutions."

Corrections and additions are identified by "redline" marking in the margins.