United States Nuclear Regulatory Commission - Protecting People and the Environment
Home > NRC Library > Document Collections > Reports Associated with Events > Power Reactor Status Reports > 2009 > April 29

Power Reactor Status Report for April 29, 2009

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

To top of page
Unit Power
Beaver Valley 1 0
Beaver Valley 2 100
Calvert Cliffs 1 100
Calvert Cliffs 2 100
FitzPatrick 100
Ginna 100
Hope Creek 1 0
Indian Point 2 100
Indian Point 3 100
Limerick 1 100
Limerick 2 100
Millstone 2 100
Millstone 3 100
Nine Mile Point 1 100
Nine Mile Point 2 100
Oyster Creek 0
Peach Bottom 2 100
Peach Bottom 3 100
Pilgrim 1 0
Salem 1 100
Salem 2 100
Seabrook 1 100
Susquehanna 1 94
Susquehanna 2 0
Three Mile Island 1 100
Vermont Yankee 100

Region 2

To top of page
Unit Power
Browns Ferry 1 100
Browns Ferry 2 0
Browns Ferry 3 100
Brunswick 1 100
Brunswick 2 21
Catawba 1 100
Catawba 2 100
Crystal River 3 100
Farley 1 0
Farley 2 100
Harris 1 0
Hatch 1 100
Hatch 2 0
McGuire 1 100
McGuire 2 100
North Anna 1 100
North Anna 2 100
Oconee 1 100
Oconee 2 100
Oconee 3 0
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 0
Sequoyah 1 0
Sequoyah 2 100
Summer 100
Surry 1 0
Surry 2 100
Turkey Point 3 0
Turkey Point 4 100
Vogtle 1 100
Vogtle 2 100
Watts Bar 1 100

Region 3

To top of page
Unit Power
Braidwood 1 100
Braidwood 2 100
Byron 1 100
Byron 2 100
Clinton 97
D.C. Cook 1 0
D.C. Cook 2 0
Davis-Besse 100
Dresden 2 98
Dresden 3 99
Duane Arnold 100
Fermi 2 0
Kewaunee 100
La Salle 1 100
La Salle 2 100
Monticello 0
Palisades 1
Perry 1 0
Point Beach 1 100
Point Beach 2 100
Prairie Island 1 100
Prairie Island 2 100
Quad Cities 1 0
Quad Cities 2 100

Region 4

To top of page
Unit Power
Arkansas Nuclear 1 100
Arkansas Nuclear 2 100
Callaway 100
Columbia Generating Station 90
Comanche Peak 1 100
Comanche Peak 2 100
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 100
Fort Calhoun 100
Grand Gulf 1 100
Palo Verde 1 100
Palo Verde 2 100
Palo Verde 3 0
River Bend 1 100
San Onofre 2 99
San Onofre 3 100
South Texas 1 100
South Texas 2 100
Waterford 3 100
Wolf Creek 1 100
Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.
  • Additional plant status information is made available on the web page after 28 days.
Page Last Reviewed/Updated Thursday, March 29, 2012
Thursday, March 29, 2012