La Salle 2 – Quarterly Performance Indicators

2Q/2017 Performance Indicators

The solid trend line represents the current reporting period.

Licensee's General Comments: none

On this page:

Link to Notes

Unplanned Scrams per 7000 Critical Hrs 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
Unplanned scrams 0 0 0 0 0 0 1.0 0
Critical hours 2045.8 2209.0 2183.0 2184.0 2208.0 2209.0 1380.6 2141.0
                 
Indicator value 0 0 0 0 0 0 0.9 0.9

To top of page

Licensee Comments: none


Link to Notes

Unplanned Power Changes per 7000 Critical Hrs 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
Unplanned power changes 0 0 0 0 0 0 0 0
Critical hours 2045.8 2209.0 2183.0 2184.0 2208.0 2209.0 1380.6 2141.0
                 
Indicator value 0 0 0 0 0 0 0 0

To top of page

Licensee Comments: none




Link to Notes

Unplanned Scrams with Complications 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
Scrams with complications 0 0 0 0 0 0 0 0
                 
                 
Indicator value 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

To top of page

Licensee Comments: none




Link to Notes

Safety System Functional Failures (BWR) 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
Safety System Functional Failures 0 0 0 0 0 0 1 0
                 
Indicator value 2 1 0 0 0 0 1 1

To top of page

Licensee Comments:
1Q/17: LER 374-2017-002




Link to Notes

Mitigating Systems Performance Index, Emergency AC Power System 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
UAI (ΔCDF) -6.33E-09 -3.22E-09 6.91E-09 6.39E-09 2.35E-08 2.35E-08 1.68E-08 1.91E-08
URI (ΔCDF) -3.04E-08 -3.04E-08 -3.66E-08 -3.41E-08 -3.41E-08 -3.41E-08 -3.41E-08 -4.03E-08
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -3.70E-08 -3.40E-08 -3.00E-08 -2.80E-08 -1.10E-08 -1.10E-08 -1.70E-08 -2.10E-08

To top of page

Licensee Comments:
2Q/17: Changed PRA Parameter(s). A new PRA model (LS2016C) specific for Unit 2 was approved in July 2017 and implemented in 2nd Quarter 2017. PRA coefficients and estimated demand changes from implementation of the surveillance frequency control program were updated in CDE to reflect the new model.
4Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
3Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
2Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented in 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model. 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented in 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model.




Link to Notes

Mitigating Systems Performance Index, High Pressure Injection System 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
UAI (ΔCDF) -1.25E-09 -1.25E-09 -4.92E-10 2.90E-09 6.39E-09 1.22E-08 1.74E-08 2.37E-08
URI (ΔCDF) -1.31E-08 -1.31E-08 -1.02E-08 -8.87E-09 -8.87E-09 -8.87E-09 -3.05E-09 -4.54E-09
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -1.40E-08 -1.40E-08 -1.10E-08 -6.00E-09 -2.50E-09 3.40E-09 1.40E-08 1.90E-08

To top of page

Licensee Comments:
2Q/17: Changed PRA Parameter(s). A new PRA model (LS2016C) specific for Unit 2 was approved in July 2017 and implemented in 2nd Quarter 2017. PRA coefficients and estimated demand changes from implementation of the surveillance frequency control program were updated in CDE to reflect the new model.
4Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
3Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
2Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented for 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model. 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented for 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model.




Link to Notes

Mitigating Systems Performance Index, Heat Removal System 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
UAI (ΔCDF) -1.26E-09 -5.84E-10 -7.03E-10 -5.22E-10 -2.36E-10 -6.50E-12 7.27E-11 -9.42E-10
URI (ΔCDF) -3.89E-09 -3.89E-09 -2.92E-09 -2.59E-09 -2.59E-09 -2.59E-09 -2.59E-09 -3.34E-09
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -5.20E-09 -4.50E-09 -3.60E-09 -3.10E-09 -2.80E-09 -2.60E-09 -2.50E-09 -4.30E-09

To top of page

Licensee Comments:
2Q/17: Changed PRA Parameter(s). A new PRA model (LS2016C) specific for Unit 2 was approved in July 2017 and implemented in 2nd Quarter 2017. PRA coefficients and estimated demand changes from implementation of the surveillance frequency control program were updated in CDE to reflect the new model.
4Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
3Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
2Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented in 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model. 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented in 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model.




Link to Notes

Mitigating Systems Performance Index, Residual Heat Removal System 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
UAI (ΔCDF) -3.55E-08 -3.55E-08 -3.42E-08 -3.42E-08 -3.42E-08 -3.42E-08 -3.42E-08 -2.53E-09
URI (ΔCDF) -4.84E-08 -4.84E-08 -4.42E-08 -4.17E-08 -4.17E-08 -4.17E-08 -4.17E-08 -2.94E-09
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -8.40E-08 -8.40E-08 -7.80E-08 -7.60E-08 -7.60E-08 -7.60E-08 -7.60E-08 -5.50E-09

To top of page

Licensee Comments:
2Q/17: Changed PRA Parameter(s). A new PRA model (LS2016C) specific for Unit 2 was approved in July 2017 and implemented in 2nd Quarter 2017. PRA coefficients and estimated demand changes from implementation of the surveillance frequency control program were updated in CDE to reflect the new model.
4Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
3Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
2Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented in 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model. 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented in 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model.




Link to Notes

Mitigating Systems Performance Index, Cooling Water Systems 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
UAI (ΔCDF) 2.71E-09 2.71E-09 1.52E-08 1.49E-08 1.76E-08 1.38E-08 1.71E-08 9.94E-09
URI (ΔCDF) -6.32E-08 -6.32E-08 -5.08E-08 -5.03E-08 -5.03E-08 -5.03E-08 -5.03E-08 -2.32E-08
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -6.00E-08 -6.00E-08 -3.60E-08 -3.50E-08 -3.30E-08 -3.70E-08 -3.30E-08 -1.30E-08

To top of page

Licensee Comments:
2Q/17: Changed PRA Parameter(s). A new PRA model (LS2016C) specific for Unit 2 was approved in July 2017 and implemented in 2nd Quarter 2017. PRA coefficients and estimated demand changes from implementation of the surveillance frequency control program were updated in CDE to reflect the new model.
4Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
3Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
2Q/16: Changed PRA Parameter(s). 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented in 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model. 1/4/17: CDF value was corrected from 2.04E-06 to 2.01E-06 and is effective 1st Quarter 2016. This correction has been documented and does not result in a change to the MSPI performance indicator color for the affected quarters.
1Q/16: Changed PRA Parameter(s). A new PRA model (LS214A) was approved in November 2015 and implemented in 1st Quarter 2016. PRA coefficients were updated in CDE to reflect the new model.




Link to Notes

Reactor Coolant System Activity 7/15 8/15 9/15 10/15 11/15 12/15 1/16 2/16 3/16 4/16 5/16 6/16
Maximum activity 0.001145 0.001214 0.001503 0.001135 0.001259 0.001089 0.001104 0.001023 0.001069 0.001125 0.001213 0.001504
Technical specification limit 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
                         
Indicator value 0.6 0.6 0.8 0.6 0.6 0.5 0.6 0.5 0.5 0.6 0.6 0.8
Reactor Coolant System Activity 7/16 8/16 9/16 10/16 11/16 12/16 1/17 2/17 3/17 4/17 5/17 6/17
Maximum activity 0.001701 0.001493 0.001549 0.001527 0.001248 0.001170 0.001152 0.001369 0.000694 0.000638 0.001092 0.000927
Technical specification limit 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
                         
Indicator value 0.9 0.7 0.8 0.8 0.6 0.6 0.6 0.7 0.3 0.3 0.5 0.5

To top of page

Licensee Comments: none




Link to Notes

Reactor Coolant System Leakage 7/15 8/15 9/15 10/15 11/15 12/15 1/16 2/16 3/16 4/16 5/16 6/16
Maximum leakage 3.400 3.900 3.200 3.200 3.300 3.300 3.400 3.500 3.800 3.700 3.600 3.800
Technical specification limit 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0
                         
Indicator value 13.6 15.6 12.8 12.8 13.2 13.2 13.6 14.0 15.2 14.8 14.4 15.2
Reactor Coolant System Leakage 7/16 8/16 9/16 10/16 11/16 12/16 1/17 2/17 3/17 4/17 5/17 6/17
Maximum leakage 3.600 3.500 3.800 3.900 3.800 3.900 3.800 3.700 2.600 2.600 2.700 2.700
Technical specification limit 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0 25.0
                         
Indicator value 14.4 14.0 15.2 15.6 15.2 15.6 15.2 14.8 10.4 10.4 10.8 10.8

To top of page

Licensee Comments: none




Link to Notes

Drill/Exercise Performance 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
Successful opportunities 62.0 63.0 13.0 141.0 98.0 36.0 24.0 100.0
Total opportunities 62.0 64.0 13.0 142.0 101.0 36.0 24.0 101.0
                 
Indicator value 98.3% 98.1% 98.1% 98.3% 98.3% 98.3% 98.2% 98.9%

To top of page

Licensee Comments:
1Q/16: During an internal assessment, it was discovered that credit taken in June 2015 did not include opportunities that should have been counted. This was corrected by increasing the number of successful drill, exercise & event opportunities from 32 to 35, and increasing the number of total drill, exercise & event opportunities from 32 to 36. This issue has been entered in the corrective action program and does not result in a change to the performance indicator color.
4Q/15: During an internal assessment, it was discovered that credit was taken in April 2015 for an opportunity that should not have been counted. This was corrected by decreasing the number of total drill, exercise and event opportunities from 51 to 50 for April 2015. This issue, which did not result in a change to performance indicator color, has been entered into the corrective action program.




Link to Notes

ERO Drill Participation 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
Participating Key personnel 68.0 67.0 67.0 63.0 62.0 62.0 63.0 65.0
Total Key personnel 68.0 67.0 67.0 63.0 62.0 62.0 63.0 65.0
                 
Indicator value 100.0% 100.0% 100.0% 100.0% 100.0% 100.0% 100.0% 100.0%

To top of page

Licensee Comments:
1Q/16: During an internal assessment, it was discovered that credit taken in February and March 2016 did not include participations that should have been counted. This was corrected by increasing the number of participating key personnel and total key personnel by two for February and March 2016. This issue has been entered into the corrective action program and does not result in a change to the performance indicator color.




Link to Notes

Alert & Notification System 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
Successful siren-tests 2208 2175 2175 2174 2170 2106 2210 2173
Total sirens-tests 2210 2176 2176 2176 2176 2108 2210 2176
                 
Indicator value 99.9% 99.9% 99.9% 99.9% 99.9% 99.9% 99.9% 99.9%

To top of page

Licensee Comments: none




Link to Notes

Occupational Exposure Control Effectiveness 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
High radiation area occurrences 0 0 0 0 0 0 0 0
Very high radiation area occurrences 0 0 0 0 0 0 0 0
Unintended exposure occurrences 0 0 0 0 0 0 0 0
Indicator value 0 0 0 0 0 0 0 0

To top of page

Licensee Comments: none




Link to Notes

RETS/ODCM Radiological Effluent 3Q/15 4Q/15 1Q/16 2Q/16 3Q/16 4Q/16 1Q/17 2Q/17
RETS/ODCM occurrences 0 0 0 0 0 0 0 0
                 
Indicator value 0 0 0 0 0 0 0 0

To top of page

Licensee Comments: none






Although the Security Cornerstone is included in the Reactor Oversight Process assessment program, the Commission has decided that specific information related to findings and performance indicators pertaining to the Security Cornerstone will not be publicly available to ensure that security information is not provided to a possible adversary. Other than the fact that a finding or performance indicator is Green or Greater-Than-Green, security related information will not be displayed on the public web page.





 
 
 
 

Current data as of: July 26, 2017

Page Last Reviewed/Updated Wednesday, June 07, 2017