Design-Specific Review Standard (DSRS) for the mPower™ Design - Chapter 9

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

NUREG-0800 SRP/DSRS Section No. NUREG-0800 SRP/DSRS Section Title Applicability of NUREG-0800 Section to mPower™ Design Comments/Additional Guidance Documents to be used for Review, etc.
9.1.1
ML070570006
Criticality Safety of Fresh and Spent Fuel Storage and Handling A) Use SRP Section "as-is" (minor comments)  
9.1.2
ML070550057
New and Spent Fuel Storage A) Use SRP Section "as-is" (minor comments) Amended to accommodate mPower™-specific single spent fuel pool shared by two units. Section III. Review Procedures Item 1. Change this to read: 1.The SAR is reviewed to determine whether the design bases and facility description section indicate the storage capacity of the design. The minimum storage capacity in the spent fuel storage pool should equal or exceed the amount of spent fuel from five years of operation at full power plus one full core discharge from each unit sharing the pool. Due to insufficient away-from-reactor storage capacity, the industry trend has been to use high-density storage racks. The reviewer evaluates high-density storage case by case. Low-density storage should be used, at a minimum, for the most recently discharged fuel to enhance the capability to cool it.
9.1.3
ML12319A063
Spent Fuel Pool Cooling and Cleanup System C) Modify SRP Section for DSRS  
9.1.4
ML070380200
Light Load Handling System (Related to Refueling) A) Use SRP Section "as-is" (minor comments)  
9.1.5
ML070380201
Overhead Heavy Load Handling Systems A) Use SRP Section "as-is" (minor comments)  
9.2.1
ML12319A068
Station Service Water System C) Modify SRP Section for DSRS  
9.2.2
ML12325A088
Reactor Auxiliary Cooling Water Systems C) Modify SRP Section for DSRS  
9.2.4
ML12319A091
Potable and Sanitary Water Systems C) Modify SRP Section for DSRS  
9.2.5
ML12319A423
Ultimate Heat Sink C) Modify SRP Section for DSRS  
9.2.6
ML12270A276
Condensate Storage Facilities C) Modify SRP Section for DSRS  
9.3.1
ML070550044
Compressed Air System A) Use SRP Section "as-is" (minor comments)  
9.3.2
ML12170A005
Process and Post Accident Sampling Systems C) Modify SRP Section for DSRS  
9.3.3
ML12319A437
Equipment and Floor Drainage System C) Modify SRP Section for DSRS  
9.3.4 Chemical and Volume Control System (PWR) Including Boron Recovery System B) Delete SRP Section for DSRS (N/A)  
9.3.5 Standby Liquid Control System (BWR) B) Delete SRP Section for DSRS (N/A)  
9.3.6 mPower Reactor Inventory Control and Purification System   This section to be released for public comment via separate FRN at a later date.
9.4.1
ML12276A130
Control Room Area Ventilation System C) Modify SRP Section for DSRS  
9.4.2
ML12272A229
Spent Fuel Pool Area Ventilation System C) Modify SRP Section for DSRS  
9.4.3
ML12276A133
Reactor Service Building HVAC Systems C) Modify SRP Section for DSRS  
9.4.4
ML12221A117
Turbine Area Ventilation System C) Modify SRP Section for DSRS  
9.4.5 Engineered Safety Feature Ventilation System B) Delete SRP Section for DSRS (N/A)  
9.5.1.1
ML090510170
Fire Protection Program A) Use SRP Section "as-is" (minor comments)  
9.5.1.2 Risk Informed (RI), Performance Based (PB) Fire Protection Program B) Delete SRP Section for DSRS (N/A)  
9.5.2
ML12277A361
Communications Systems C) Modify SRP Section for DSRS  
9.5.3
ML12319A516
Lighting Systems C) Modify SRP Section for DSRS  
9.5.4
ML070680388
Emergency Diesel Engine Fuel Oil Storage and Transfer System A) Use SRP Section "as-is" (minor comments) SRP Section is in the process of an update.
9.5.5
ML070550035
Emergency Diesel Engine Cooling Water System A) Use SRP Section "as-is" (minor comments) SRP Section is in the process of an update.
9.5.6
ML070550034
Emergency Diesel Engine Starting System A) Use SRP Section "as-is" (minor comments) SRP Section is in the process of an update.
9.5.7
ML070460354
Emergency Diesel Engine Lubrication System A) Use SRP Section "as-is" (minor comments) SRP Section is in the process of an update.
9.5.8
ML070550033
Emergency Diesel Engine Combustion Air Intake and Exhaust System A) Use SRP Section "as-is" (minor comments) SRP Section is in the process of an update.

Page Last Reviewed/Updated Thursday, September 15, 2022