NUREG-0800 SRP/DSRS Section No. |
NUREG-0800 SRP/DSRS Section Title |
Applicability of NUREG-0800 Section to mPower™ Design |
Comments/Additional Guidance Documents to be used for Review, etc. |
9.1.1
ML070570006 |
Criticality Safety of Fresh and Spent Fuel Storage and Handling |
A) Use SRP Section "as-is" (minor comments) |
|
9.1.2
ML070550057 |
New and Spent Fuel Storage |
A) Use SRP Section "as-is" (minor comments) |
Amended to accommodate mPower™-specific single spent fuel pool shared by two units. Section III. Review Procedures Item 1. Change this to read: 1.The SAR is reviewed to determine whether the design bases and facility description section indicate the storage capacity of the design. The minimum storage capacity in the spent fuel storage pool should equal or exceed the amount of spent fuel from five years of operation at full power plus one full core discharge from each unit sharing the pool. Due to insufficient away-from-reactor storage capacity, the industry trend has been to use high-density storage racks. The reviewer evaluates high-density storage case by case. Low-density storage should be used, at a minimum, for the most recently discharged fuel to enhance the capability to cool it. |
9.1.3
ML12319A063 |
Spent Fuel Pool Cooling and Cleanup System |
C) Modify SRP Section for DSRS |
|
9.1.4
ML070380200 |
Light Load Handling System (Related to Refueling) |
A) Use SRP Section "as-is" (minor comments) |
|
9.1.5
ML070380201 |
Overhead Heavy Load Handling Systems |
A) Use SRP Section "as-is" (minor comments) |
|
9.2.1
ML12319A068 |
Station Service Water System |
C) Modify SRP Section for DSRS |
|
9.2.2
ML12325A088 |
Reactor Auxiliary Cooling Water Systems |
C) Modify SRP Section for DSRS |
|
9.2.4
ML12319A091 |
Potable and Sanitary Water Systems |
C) Modify SRP Section for DSRS |
|
9.2.5
ML12319A423 |
Ultimate Heat Sink |
C) Modify SRP Section for DSRS |
|
9.2.6
ML12270A276 |
Condensate Storage Facilities |
C) Modify SRP Section for DSRS |
|
9.3.1
ML070550044 |
Compressed Air System |
A) Use SRP Section "as-is" (minor comments) |
|
9.3.2
ML12170A005 |
Process and Post Accident Sampling Systems |
C) Modify SRP Section for DSRS |
|
9.3.3
ML12319A437 |
Equipment and Floor Drainage System |
C) Modify SRP Section for DSRS |
|
9.3.4 |
Chemical and Volume Control System (PWR) Including Boron Recovery System |
B) Delete SRP Section for DSRS (N/A) |
|
9.3.5 |
Standby Liquid Control System (BWR) |
B) Delete SRP Section for DSRS (N/A) |
|
9.3.6 |
mPower Reactor Inventory Control and Purification System |
|
This section to be released for public comment via separate FRN at a later date. |
9.4.1
ML12276A130 |
Control Room Area Ventilation System |
C) Modify SRP Section for DSRS |
|
9.4.2
ML12272A229 |
Spent Fuel Pool Area Ventilation System |
C) Modify SRP Section for DSRS |
|
9.4.3
ML12276A133 |
Reactor Service Building HVAC Systems |
C) Modify SRP Section for DSRS |
|
9.4.4
ML12221A117 |
Turbine Area Ventilation System |
C) Modify SRP Section for DSRS |
|
9.4.5 |
Engineered Safety Feature Ventilation System |
B) Delete SRP Section for DSRS (N/A) |
|
9.5.1.1
ML090510170 |
Fire Protection Program |
A) Use SRP Section "as-is" (minor comments) |
|
9.5.1.2 |
Risk Informed (RI), Performance Based (PB) Fire Protection Program |
B) Delete SRP Section for DSRS (N/A) |
|
9.5.2
ML12277A361 |
Communications Systems |
C) Modify SRP Section for DSRS |
|
9.5.3
ML12319A516 |
Lighting Systems |
C) Modify SRP Section for DSRS |
|
9.5.4
ML070680388 |
Emergency Diesel Engine Fuel Oil Storage and Transfer System |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update. |
9.5.5
ML070550035 |
Emergency Diesel Engine Cooling Water System |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update. |
9.5.6
ML070550034 |
Emergency Diesel Engine Starting System |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update. |
9.5.7
ML070460354 |
Emergency Diesel Engine Lubrication System |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update. |
9.5.8
ML070550033 |
Emergency Diesel Engine Combustion Air Intake and Exhaust System |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update. |