NUREG-0800 SRP/DSRS Section No. |
NUREG-0800 SRP/DSRS Section Title |
Applicability of NUREG-0800 Section to mPower™ Design |
Comments/Additional Guidance Documents to be used for Review, etc. |
3.2.1
ML12272A013 |
Seismic Classification |
C) Modify SRP Section for DSRS |
|
3.2.2
ML12272A015 |
System Quality Group Classification |
C) Modify SRP Section for DSRS |
|
3.3.1
ML12324A156 |
Severe Wind Loading |
C) Modify SRP Section for DSRS |
This section was formerly entitled "Wind Loads". |
3.3.2
ML12324A166 |
Extreme Wind Loads (Tornado and Hurricane Loads) |
C) Modify SRP Section for DSRS |
This section was formerly entitled "Tornado Loads". |
3.4.1
ML12312A148 |
Internal Flood Protection for Onsite Equipment Failure |
C) Modify SRP Section for DSRS |
|
3.4.2
ML12324A190 |
Protection of Structures Against Flood From External Sources |
C) Modify SRP Section for DSRS |
This section was formerly entitled "Analysis Procedures". |
3.5.1.1
ML12313A158 |
Internally Generated Missiles (Outside Containment) |
C) Modify SRP Section for DSRS |
|
3.5.1.2
ML12313A396 |
Internally Generated Missiles (Inside Containment) |
C) Modify SRP Section for DSRS |
|
3.5.1.3
ML12272A209 |
Turbine Missiles |
C) Modify SRP Section for DSRS |
|
3.5.1.4
ML12313A399 |
Missiles Generated by Extreme Winds |
C) Modify SRP Section for DSRS |
This section was formerly entitled "Missiles Generated by Tornadoes and Extreme Winds" |
3.5.1.5
ML12318A151 |
Site Proximity Missiles (Except Aircraft) |
C) Modify SRP Section for DSRS |
|
3.5.1.6
ML12318A198 |
Aircraft Hazards |
C) Modify SRP Section for DSRS |
|
3.5.2
ML12313A457 |
Structures, Systems, and Components To Be Protected From Externally Generated Missiles |
C) Modify SRP Section for DSRS |
|
3.5.3
ML12222A003 |
Barrier Design Procedures |
C) Modify SRP Section for DSRS |
|
3.6.1
ML070550032 |
Plant Design for Protection Against Postulated Piping Failures in Fluid Systems Outside Containment |
A) Use SRP Section "as-is" (minor comments) |
Replace this first sentence of "AREAS OF REVIEW" with the following: The plant design for protection against piping failures outside containment is reviewed to ensure that environmental effects of such failures would not cause the loss of needed functions of safety-related or risk-significant systems and to ensure that the plant could be safely shut down in the event of such failures. An SSC may be classified as:
- Safety-related risk-significant
- Safety-related non-risk-significant
- Non safety-related risk-significant
- Nonsafety-related non-risk-significant
The mPowerTM application will include the classification of SSCs, a list of risk-significant SSCs, and a list of RTNSS equipment. Based on this information, the staff will review according to DSRS Section 3.2, SRP Sections 17.4 and 19.3 to confirm the determination of the safety-related and risk-significant SSCs. If the SSC belongs in the first two classifications above or if it is determined as part of the SRP 19.3 "Augmented Design Standard" review that the SSC is RTNSS "B", the review described in this DSRS Section is applied. For the purpose of brevity in this section, the first two categories above and the RTNSS "B" SSCs will be designated as "SSCs subject to protection against piping failures outside containment."
|
3.6.2
ML12230A013 |
Determination of Rupture Locations and Dynamic Effects Associated with the Postulated Rupture of Piping |
C) Modify SRP Section for DSRS |
|
3.6.3 |
Leak-Before-Break Evaluation Procedures |
B) Delete SRP Section for DSRS (N/A) |
|
3.7.1
ML13099A204 |
Seismic Design Parameters |
C) Modify SRP Section for DSRS |
|
3.7.2
ML13099A205 |
Seismic System Analysis |
C) Modify SRP Section for DSRS |
|
3.7.3
ML13099A209 |
Seismic Subsystem Analysis |
C) Modify SRP Section for DSRS |
|
3.7.4
ML070460349 |
Seismic Instrumentation |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update. |
3.8.1 |
Concrete Containment |
B) Delete SRP Section for DSRS (N/A) |
|
3.8.2
ML13099A298 |
Steel Containment |
C) Modify SRP Section for DSRS |
|
3.8.3
ML13099A312 |
Concrete and Steel Internal Structures of Steel Containments |
C) Modify SRP Section for DSRS |
|
3.8.4
ML13099A316 |
Other Seismic Category I Structures |
C) Modify SRP Section for DSRS |
|
3.8.5
ML13099A319 |
Foundations |
C) Modify SRP Section for DSRS |
|
3.9.1
ML12272A018 |
Special Topics for Mechanical Components |
C) Modify SRP Section for DSRS |
|
3.9.2
ML070230008 |
Dynamic Testing and Analysis of Systems, Components, and Equipment |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update.
Additional considerations:
- ASME Code AG-1-1997 references should be replaced with ASME Code AG-1-2009.
- GDC 4 of Acceptance Criteria should require SSCs be designed to accommodate the effects of and to be compatible with the environmental conditions associated with normal operation, maintenance, testing, and postulated accidents, including loss-of-cooling accidents.
- RG 1.20 provides guidance and not requirements.
- DG-1163 has been replaced with RG 1.20.
|
3.9.3
ML070430397 |
ASME Code Class 1, 2, and 3 Components, Component Supports, and Core Support Structures |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update.
Additional consideration:
- The applicants SAR should include the description of snubber operability assurance program requirements that the snubber manufacturer submits to the purchaser for review and acceptance per ASME OM, ISTD Code.
|
3.9.4
ML12272A020 |
Control Rod Drive Systems |
C) Modify SRP Section for DSRS |
|
3.9.5
ML12272A077 |
Reactor Pressure Vessel Internals |
C) Modify SRP Section for DSRS |
|
3.9.6
ML12272A217 |
Functional Design, Qualification, and Inservice Testing Programs for Pumps, Valves, and Dynamic Restraints |
C) Modify SRP Section for DSRS |
|
3.9.7 |
Risk-Informed Inservice Testing of Pumps and Valves |
B) Delete SRP Section for DSRS (N/A) |
|
3.9.8 |
Risk-Informed Inservice Inspection of Piping |
B) Delete SRP Section for DSRS (N/A) |
|
3.10
ML070720037 |
Seismic and Dynamic Qualification of Mechanical and Electrical Equipment |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update.
Clarification of terminology SRP 3.10, page 3.10-4, number 3. replace with: "GDC 4 as it relates to qualifying equipment as capable of withstanding the environmental conditions associated with normal operation, maintenance, testing, and postulated accidents, including loss-of-coolant accidents (LOCAs), as well as dynamic effects (e.g., missiles, pipe whip, and jet impingement forces) that may result from equipment failures and from events and conditions outside the plant."
|
3.11
ML12277A018 |
Environmental Qualification of Mechanical and Electrical Equipment |
C) Modify SRP Section for DSRS |
|
3.12
ML070040002 |
ASME Code Class 1, 2, and 3 Piping Systems and Associated Supports Design |
A) Use SRP Section "as-is" (minor comments) |
SRP Section is in the process of an update. |
3.13
ML12272A214 |
Threaded Fasteners - ASME Code Class 1, 2, and 3 |
C) Modify SRP Section for DSRS |
|
BTP 3-1 |
Classification of Main Steam Components Other than the Reactor Coolant Pressure Boundary for BWR Plants (Former Section 3.2.2, Appendix A, BTP has been separated into an individual section.) |
B) Delete SRP Section for DSRS (N/A) |
|
BTP 3-2 |
Classification of BWR/6 Main Steam and Feedwater Components Other than the Reactor Coolant Pressure Boundary (Former Section 3.2.2, Appendix B, BTP has been separated into an individual section.) |
B) Delete SRP Section for DSRS (N/A) |
|
BTP 3-3
ML070800027 |
Protection Against Postulated Piping Failures Influid Systems Outside Containment |
A) Use SRP Section "as-is" (minor comments) |
|
BTP 3-4
ML12272A102 |
Postulated Rupture Locations in Fluid System Piping Inside and Outside Containment |
C) Modify SRP Section for DSRS |
|