Home > NRC Library > ADAMS Public Documents
Forwards LERs 83-088/03L-0,83-089/03L-0,83-090/03L-0 & 83-091/03L-0.
Accession Number: ML20078H357
Date Released: Wednesday, April 1, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20078H352 - Forwards LERs 83-088/03L-0,83-089/03L-0,83-090/03L-0 & 83-091/03L-0. (1 page(s), 10/5/1983)
- ML20078H359 - LER 83-088/03L-0:on 830912,nonfunctional fire seal discovered.Caused by fire seal pulled while installing another cable.Fire seal repaired & contractor personnel retrained. (1 page(s), 10/5/1983)
- ML20078H363 - LER 83-089/03L-0:on 830915,west containment spray pump discharge valve position lights noted out & breaker open. Cause could not be determined.No corrective action planned. (1 page(s), 10/5/1983)
- ML20078H366 - LER 83-090/03L-0:on 830920,during surveillance test on solid-state protection sys,two logic positions tested unsatisfactorily.Caused by defective universal card A-311. Logic card replaced. (1 page(s), 10/5/1983)
- ML20078H371 - LER 83-091/03L-0:on 830906,pressurizer pressure dropped below Tech Spec limit.Caused by combination of individual pressurizer heater circuit breakers tripping & high valve seat leakage.Load reduced. (2 page(s), 10/5/1983)