Home > NRC Library > ADAMS Public Documents
Forwards Nonroutine Environ Operating Repts 50-219/82-4, 50-219/82-5,50-219/82-6 & 50-219/82-7.
Accession Number: ML20064E696
Date Released: Wednesday, March 18, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20064E692 - Forwards Nonroutine Environ Operating Repts 50-219/82-4, 50-219/82-5,50-219/82-6 & 50-219/82-7. (1 page(s), 12/21/1982)
- ML20064E706 - RO 82-4:on 821116,dilution pump 1-3 tripped off leaving only pump 1-2 in operation.Caused by low seal water pressure due to debris clogging seal water strainer.Debris cleared from strainer.Pump refurbishment program planned. (2 page(s), 12/21/1982)
- ML20064E715 - RO 82-5:on 821122,dilution pump 1-3 removed from svc.Caused by dc ground on control switch in vacuum breaker valve due to water leakage through seal on cover plate.Appropriate repairs performed. (2 page(s), 12/21/1982)
- ML20064E722 - RO 82-6:on 821130,dilution pump 1-2 removed from svc.Caused by mud & debris clogging grates,blocking water flow to dilution pump.Mud & debris removed.Total dilution pump refurbishment program planned. (2 page(s), 12/21/1982)
- ML20064E727 - RO 82-7:on 821201,dilution pump 1-3 removed from svc.Caused by mud & debris clogging grates,blocking water flow to dilution pump.Mud & debris removed.Total dilution pump refurbishment program planned. (2 page(s), 12/21/1982)