U.S. Nuclear Regulatory Commission Operations Center Event Reports For 11/10/2015 - 11/12/2015 ** EVENT NUMBERS ** | Non-Agreement State | Event Number: 51461 | Rep Org: DEPARTMENT OF THE ARMY ABERDEEN Licensee: DEPARTMENT OF THE ARMY Region: 1 City: ABERDEEN State: MD County: License #: 19-31127-01 Agreement: Y Docket: 030-3713 NRC Notified By: BARRY SCOTT DAVIDSON HQ OPS Officer: DANIEL MILLS | Notification Date: 10/09/2015 Notification Time: 09:32 [ET] Event Date: 10/08/2015 Event Time: [EDT] Last Update Date: 11/10/2015 | Emergency Class: NON EMERGENCY 10 CFR Section: 20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X | Person (Organization): BRICE BICKETT (R1DO) NMSS_EVENTS_NOTIFIC (EMAI) CNSNS (MEXICO) (EMAI) MATTHEW HAHN (ILTA) ANN MARIE STONE (R3DO) NICK TAYLOR (R4DO) | This material event contains a "Less than Cat 3 " level of radioactive material. | Event Text SOURCE LOST DURING SHIPPING A 1.2 mCi Californium-252 sealed source was shipped from Aberdeen Proving Ground, MD to Fort Irwin, CA via common carrier. The source did not arrive as expected and the common carrier has initiated a trace. Licensee will notify NRC Region 1. * * * UPDATE FROM SCOTT DAVIDSON TO DANIEL MILLS AT 1328 EST ON 11/10/15 * * * The following was received via email: "The package did not arrive at its destination (Fort Irwin, CA) but was delivered to Dugway Proving Ground, UT (DPG). We [Department of the Army] were notified on 3 NOV 15 that the package was at DPG with a photo of the package showing the same serial number as the package that was shipped. The package [was held] at DPG awaiting coordinating instructions to have it returned to the unit responsible for shipping the package." The package has since been received and will be repackaged for shipment to its original destination. Notified R1DO (Arner), R3DO (Kozak), R4DO (Gaddy), ILTAB (Wray), NMSS Events Notification (email), CNSNS (Mexico - via fax) THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf | Agreement State | Event Number: 51511 | Rep Org: PA BUREAU OF RADIATION PROTECTION Licensee: ST. LUKE'S UNIVERSITY HEALTH NETWORK Region: 1 City: BETHLEHEM State: PA County: License #: PA-0073 Agreement: Y Docket: NRC Notified By: JOSEPH MELNIC HQ OPS Officer: DANIEL MILLS | Notification Date: 11/02/2015 Notification Time: 10:34 [ET] Event Date: 10/30/2015 Event Time: [EST] Last Update Date: 11/02/2015 | Emergency Class: NON EMERGENCY 10 CFR Section: AGREEMENT STATE | Person (Organization): JOHN ROGGE (R1DO) NMSS_EVENTS_NOTIFIC (EMAI) | Event Text UNDERDOSE DUE TO MALFUNCTION OF THE DOSE DELIVERY SYSTEM The following was received via email: "During the administration of an yttrium-90 SIR Spheresr procedure, a portion of the dose began to leak out of the top of the vial containing the activity. To prevent contamination of the interventional radiographic suite, the medical physicist and authorized user aborted the administration. It is estimated that only 10 - 20% of the dose noted on the written directive was actually delivered to the patient. The patient and radiation safety officer were notified immediately following the cancellation of the administration and the patient has agreed to be treated again in the near future. Knowing the exact administered activity is nearly impossible given the characteristics of the procedure and radiopharmaceutical. No harm is expected to the patient. "The event seems to be due to a malfunction of the dose delivery system. It appeared to the interventional radiologist that the leak was located at the top of the dose vial and likely at the original puncture site of the radiopharmacy upon preparation of the dose for administration." Event Report # PA150028 A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. | Power Reactor | Event Number: 51526 | Facility: COLUMBIA GENERATING STATION Region: 4 State: WA Unit: [2] [ ] [ ] RX Type: [2] GE-5 NRC Notified By: BRYAN HEAVILIN HQ OPS Officer: DONALD NORWOOD | Notification Date: 11/10/2015 Notification Time: 04:15 [ET] Event Date: 11/09/2015 Event Time: 20:40 [PST] Last Update Date: 11/10/2015 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION | Person (Organization): DAVID PROULX (R4DO) | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text REACTOR BUILDING VACUUM LESS THAN TECHNICAL SPECIFICATIONS REQUIREMENT "At 2040 PST on 11/9/2015, Reactor Building (Secondary Containment) pressure increased to above the Technical Specification Surveillance requirement of 0.25 inches vacuum water gauge for approximately seven minutes. Operators took action to manually start Standby Gas Treatment System to restore Reactor Building pressure. This event is reportable as an event that could have prevented fulfillment of a safety function needed to control the release of radiation and mitigate the consequences of an accident. The cause of the event is under investigation. "There were no radiological releases associated with the event. "No safety system actuations or isolations occurred. "The licensee notified the NRC Resident Inspector." | Power Reactor | Event Number: 51527 | Facility: SEQUOYAH Region: 2 State: TN Unit: [ ] [2] [ ] RX Type: [1] W-4-LP,[2] W-4-LP NRC Notified By: CLAY CAMENISCH HQ OPS Officer: DANIEL MILLS | Notification Date: 11/10/2015 Notification Time: 20:13 [ET] Event Date: 11/10/2015 Event Time: 15:02 [EST] Last Update Date: 11/10/2015 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(v)(B) - POT RHR INOP 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION 50.72(b)(3)(ii)(B) - UNANALYZED CONDITION | Person (Organization): FRANK EHRHARDT (R2DO) | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 2 | N | Y | 81 | Power Operation | 81 | Power Operation | Event Text UNANALYZED CONDITION DUE TO DEBRIS DROPPED INTO REACTOR CAVITY EQUIPMENT PIT "On 11/10/2015 at 1502 [EST], Unit 2 MCR [main control room] was notified by workers in containment that 2 ice suits had been dropped into the Unit 2 Containment Reactor Cavity Equipment Pit. Based upon size and location of the dropped suits, Unit 2 entered LCO 3.6.15 (Containment Recirculation Drains) Condition B and LCO 3.0.3 for refueling canal drains being inoperable. The two refueling canal drains and the ice condenser drains function with the ice bed, Containment Spray System and ECCS to limit the pressure and temperature that could be expected following a DBA [Design Basis Accident]. Following performance of a Safety Function Determination it was determined that, during the short duration when both coats were in the process of being retrieved, they could have potentially clogged the drains and prevented the fulfillment of safety functions if there was a DBA. Both suits were retrieved from the equipment pit by 1556 [EST] and all LCO conditions were exited." The licensee notified the NRC Resident Inspector. | Power Reactor | Event Number: 51528 | Facility: PRAIRIE ISLAND Region: 3 State: MN Unit: [1] [2] [ ] RX Type: [1] W-2-LP,[2] W-2-LP NRC Notified By: NATHAN BIBUS HQ OPS Officer: DANIEL MILLS | Notification Date: 11/11/2015 Notification Time: 11:48 [ET] Event Date: 11/11/2015 Event Time: 08:26 [CST] Last Update Date: 11/11/2015 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): LAURA KOZAK (R3DO) | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | 2 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown | Event Text SHIELD BUILDING VENT GAS RADIATION MONITOR OUT OF SERVICE FOR PLANNED MAINTENANCE "At 0826 CST on 11/11/2015, 1R-22, Shield Building Vent Gas Radiation Monitor, was removed from service for planned maintenance. This monitor has no compensatory measure that will allow timely classification of two Emergency Action Levels (EALs) - NUE (Notification of Unusual Event) and Alert classifications - when out of service. It is also used for offsite dose projection calculations. This results in a Loss of Emergency Assessment Capability while 1R-22 is out of service. This is a reportable condition in accordance with 10 CFR 50.72(b)(3)(xiii). "Unit 1 Shield Building Ventilation Stack is also monitored by high range monitor, 1R-50, which is used for the same purpose in Site Area or General Emergency classifications. 1R-50 is being monitored and is indicating normal values. There are no radioactive leaks that will impact the Shield Building as evidenced by normal readings on 1R-22 prior to its removal from service. The duration of this maintenance is scheduled for 24 hours and will continue until the monitor is returned to service. Maintenance will not result in the unplanned release of radioactivity to the environment and will not adversely affect the safe operation of the plant or health and safety of the public. "The licensee has notified the NRC Resident Inspector." | Power Reactor | Event Number: 51530 | Facility: LASALLE Region: 3 State: IL Unit: [1] [2] [ ] RX Type: [1] GE-5,[2] GE-5 NRC Notified By: WAYNE CLAYTON HQ OPS Officer: DANIEL MILLS | Notification Date: 11/11/2015 Notification Time: 19:40 [ET] Event Date: 11/11/2015 Event Time: 13:44 [CST] Last Update Date: 11/11/2015 | Emergency Class: NON EMERGENCY 10 CFR Section: 50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE | Person (Organization): LAURA KOZAK (R3DO) | Unit | SCRAM Code | RX CRIT | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode | 1 | N | Y | 100 | Power Operation | 100 | Power Operation | 2 | N | Y | 100 | Power Operation | 100 | Power Operation | Event Text SEISMIC MONITOR INOPERABLE "At 1344 CST on 11/11/15, the seismic monitor was found inoperable. The seismic monitor was inoperable such that emergency classification at the ALERT level could not be obtained with site instrumentation. "The loss of assessment capability is reportable to the NRC within 8 hours of discovery in accordance with 10 CFR 50.72(b)(3)(xiii). "[The NRC] Senior Resident Inspector has been notified." | |