Appendix B, ''Quality Assurance Criteria for Nuclear Power Plants and Fuel
Reprocessing Plants," to 10 CER Part 50, "Licensing of Production and Utilization
Facilities," establishes quality assurance requirements for the operation of
nuclear lower plant safety-related structures, Systems, and components. This
regulatory guide describes a method acceptable to the NRC staff for complying
with the Commission's regulations with regard to overall quality assurance program
requirements for the operation phase of nuclear power plants. The Advisory Committee
on Reactor Safeguards has been consulted concerning this guide and has concurred
in the regulatory position.
Subcommittee ANS-3, Reactor Operations, of the American Nuclear Society Standards
Committee developed ANSI N18.7-l972, which contained criteria for administrative
controls for nuclear power plants during operation. This standard, along with
ANSI N45.2. 1971, ''Quality Assurance Program Requirements for Nuclear Power
Plants," was endorsed by Regulatory Guide 1.33. The dual endorsement was necessary
in order for the guidance contained in the regulatory guide to be consistent
with the requirements of Appendix B to 10 CFR Part 50; however, this dual endorsement
caused some confusion among users. To clarify this situation, ANSI NI 8.7-1972
was revised so that a single standard would define the general quality assurance
program "requirements" for the operation phase. This revised standard was approved
by the American National Standards Committee N IS, Nuclear Design Criteria It
was subsequently approved and designated N18.7-1976/ANS-3.2, "Administrative
Controls and Quality Assurance for the Operational Phase of Nuclear Power Plants,"(1)
by the American National Standards Institute on February 19, 1976.
There had been some uncertainty with regard to the NRC staff's position when
a regulatory guide endorses, as an acceptable method, the "guidelines" as well
as the "requirements" included in a standard. The NRC staff has evaluated the
guidelines contained in N18.7-1976/ANS-3.2 with respect to importance to safety.
Revision I of this regulatory guide clarified the NRC staff's position on the
"requirements" and "guidelines" included in ANSI N 18.7- 1976/ANS- 3.2. Where
conformance to the recommendations of this regulatory guide is indicated in
an application without further qualification. this indicates the applicant will
comply with the ''requirements'' of ANSI N18.7- 1976/AN5-3.2, as supplemented
or modified by the regulatory position of this guide.
Section I, "Scope," of ANSI N18.7-1976/ANS-3.2 states that this standard contains
criteria for administrative controls and quality assurance for nuclear power
plants during the operational phase of plant life and that (his phase is generally
considered to commence with initial fuel loading, except forcer-lain preoperational
activities. In this regard, a separate regulatory guide addressing the quality
assurance program for the preoperational phase will be issued. Other regulatory
guides may be issued or this regulatory guide may be revised, if necessary,
to amplify the general requirernents contained in this standard.
The overall quality assurance program requirements (or the operation phase
that are included in ANSI NIS .7-I 976/ANS-3.2 are acceptable to the NRC staff
and provide an adequate basis (or complying with the quality assurance program
requirements or Appendix B to 10 CFR Part 50, subject to the following:
The purpose of this section is to provide information to applicants and licensees
regarding the NRC staff's plans for using this regulatory guide.
This guide reflects current NRC practice. Therefore, except in those cases
in which the applicant proposes an acceptable alternative method for complying
with the specified portions of the Commission's regulations, the method described
herein is being and will continue to be used in the evaluation of submittals
for operating license applications until this guide is revised as a result of
suggestions from the public or additional staff review.
The following are typical safety-related activities that should be covered
by written procedures. This appendix is not intended as an inclusive listing
of all needed procedures since many other activities carried out during the
operation phase of nuclear power plants should be covered by procedures not
included in this list.
| 1. |
Administrative Procedures |
| |
a. |
Security and Visitor Control |
| |
b. |
Authorities and Responsibilities for Safe Operation and Shutdown |
| |
c. |
Equipment Control (e.g., locking and tagging) |
| |
d. |
Procedure Adherence and Temporary Change Method |
| |
e. |
Procedure Review and Approval |
| |
f. |
Schedule for Surveillance Tests and Calibration |
| |
g. |
Shift and Relief Turnover |
| |
h. |
Log Entries, Record Retention, and Review Procedures |
| |
i. |
Access
to Containment |
| |
j. |
Bypass of Safety Functions and Jumper Control |
| |
k. |
Maintenance of Minimum Shift Complement and Call-In of Personnel |
| |
l. |
Plant Fire Protection Program |
| |
m. |
Communication System Procedures |
| 2. |
General Plant Operating Procedures |
| |
a. |
Cold Shutdown to Hot Standby |
| |
b. |
Hot Standby to Minimum Load (nuclear start-up) |
| |
c. |
Recovery from Reactor Trip |
| |
d. |
Operation at Hot Standby |
| |
e. |
Turbine Startup and Synchronization of Generator |
| |
f. |
Changing Load and Load Follow (if applicable) |
| |
g. |
Power Operation and Process Monitoring |
| |
h. |
Power Operation with less than Full Reactor Coolant Plow |
| |
i. |
Plant Shutdown to Hot Standby |
| |
j. |
Hot Standby to Cold Shutdown |
| |
k. |
Preparation for Refueling and Refueling Equipment Operation |
| |
l. |
Refueling and Core Alterations |
| 3. |
Procedures for Startup. Operation. and Shutdown of Safety
-Related PWR Systems |
| |
Instructions for energizing, filling, venting, drain-jog,
startup, shutdown, and changing modes of operation should be prepared, as
appropriate, for the following Systems: |
| |
a. |
Reactor Coolant System |
| |
b. |
Control Rod Drive System (including part-length rods) |
| |
c. |
Shutdown Cooling System |
| |
d. |
Emergency Core Cooling System |
| |
e. |
Component Cooling Water System |
| |
f. |
Containment |
| |
|
(1) |
Maintaining Containment Integrity |
| |
|
(2) |
Special Containment Systems |
| |
|
|
(a) |
Atmosphere |
| |
|
|
(b) |
Subatmospheric |
| |
|
|
(c) |
Double-Wall Containment with Controlled Interspace |
| |
|
|
(d) |
Ice Condenser |
| |
|
(3) |
Containment Ventilation System |
| |
|
(4) |
Containment Cooling System |
| |
g. |
Atmosphere Cleanup Systems |
| |
h. |
Fuel Storage Pool Purification and Cooling System |
| |
i. |
Main Steam System |
| |
j. |
Pressurizer Pressure and Spray Control Systems |
| |
k. |
Feedwater System (feedwater pumps to steam generator) |
| |
l. |
Auxiliary Feedwater System |
| |
m. |
Service Water System |
| |
n. |
Chemical and Volume Control System (including Letdown/Purification
System) |
| |
o. |
Auxiliary or Reactor Building Heating and Ventilation |
| |
p. |
Control Room Heating and Ventilation |
| |
q. |
Radwaste Building Heating and Ventilation |
| |
r. |
Instrument Air System |
| |
s. |
Electrical System |
| |
|
(1) |
Offsite (access circuits) |
| |
|
(2) |
Onsite |
| |
|
|
(a) |
Emergency Power Sources (e.g., diesel generator, batteries) |
| |
|
|
(b) |
A.C. System |
| |
|
|
(c) |
D.C. System |
| |
t. |
Nuclear Instrument System |
| |
|
(1) |
Source Range |
| |
|
(2) |
Intermediate Range |
| |
|
(3) |
Power Range |
| |
|
(4) |
Income System |
| |
u. |
Reactor Control and Protection System |
| |
v. |
Hydrogen Recombiner |
| 4. |
Procedure for Startup, Operation, and Shutdown of Safety-Related
BWR Systems |
| |
Instructions for energizing, filling, venting, draining, startup,
shutdown, and changing modes of operation should -be prepared, as appropriate,
for the following Systems: |
| |
a. |
Nuclear Steam Supply System (Vessel and Recirculating System) |
| |
b. |
Control Rod Drive System |
| |
c. |
Reactor Cleanup System |
| |
d. |
Liquid Poison System (Standby Liquid Control System) |
| |
e. |
Shutdown Cooling and Reactor Vessel Head Spray System |
| |
f. |
High Pressure Coolant Injection |
| |
g. |
Reactor Core Isolation Cooling System |
| |
h. |
Emergency Core Cooling Systems |
| |
i. |
Closed Cooling Water System |
| |
j. |
Containment |
| |
|
(1) |
Maintaining Integrity |
| |
|
(2) |
Containment Ventilation System |
| |
|
(3) |
Inerting and deinerting |
| |
k. |
Fuel Storage Pool Purification and Cooling System |
| |
l. |
Main Steam System (reactor vessel to turbine) |
| |
m. |
Turbine-Generator System |
| |
n. |
Condensate System (hotwell to feedwater pumps, including demineralizers
and resin regeneration) |
| |
o. |
Feedwater System (feedwater pumps to reactor vessel) |
| |
p. |
Makeup System (filtration, purification, and water transfer) |
| |
q. |
Service Water System |
| |
r. |
Reactor Building Heating and Ventilation Systems |
| |
s. |
Control Room Heating and Ventilation Systems |
| |
t. |
Radwaste Building Heating and Ventilation Systems |
| |
u. |
Standby Gas Treatment System |
| |
v. |
Instrument Air System |
| |
w. |
Electrical System |
| |
|
(1) |
Offsite (access circuits) |
| |
|
(2) |
Onsite |
| |
|
|
(a) |
Emergency Power Sources (e.g., diesel generator, batteries) |
| |
|
|
(b) |
A.C. System |
| |
|
|
(c) |
D.C. System |
| |
x. |
Nuclear Instrument System |
| |
|
(1) |
Source Range |
| |
|
(2) |
Intermediate Range |
| |
|
(3) |
Power Range |
| |
|
(4) |
TIP System |
| |
y. |
Reactor Protection System |
| |
z. |
Rod Worth Minimizer |
| 5. |
Procedures for Abnormal, Offnormal, or Alarm Conditions |
| |
Since these procedures are numerous and correspond to the
number of alarm annunciators, the procedures are not individually listed.
Each safety related annunciator should have its own written procedure, which
should normally contain (1) the meaning of the annunciator, (2) the source
of the signal, (3) the immediate action that is to occur automatically.
(4) the immediate operation action, and (5) the long-range actions. |
| 6. |
Procedures for Combating Emergencies and Other Significant
Events |
| |
a. |
Loss of Coolant (including significant PWR steam generator
leaks) (inside and outside primary containment) (large and small, including
leak-rate determination) |
| |
b. |
Loss of Instrument Air |
| |
c. |
Loss of Electrical Power (and/or degraded power sources) |
| |
d. |
Loss of Core Coolant Flow |
| |
e. |
Loss of Condenser Vacuum |
| |
f. |
Loss of Containment Integrity |
| |
g. |
Loss of Service Water |
| |
h. |
Loss of Shutdown Cooling Loss of Component Cooling System
and Cooling to Individual Components |
| |
j. |
Loss of Feedwater or Feedwater System Failure |
| |
k. |
Loss of Protective System Channel |
| |
l. |
Mispositioned Control Rod or Rods (and rod drops) |
| |
m. |
Inability to Drive Control Rods |
| |
n. |
Conditions Requiring Use of Emergency Boration or Standby
Liquid Control System |
| |
o. |
Fuel Cladding Failure or High Activity in Reactor Coolant
or Offgas |
| |
p. |
Fire in Control Room or Forced Evacuation of Control Room |
| |
q. |
Turbine and Generator Trips |
| |
r. |
Other Expected Transients that may be Applicable |
| |
s. |
Malfunction of Automatic Reactivity Control System |
| |
t. |
Malfunction of Pressure Control System |
| |
u. |
Reactor Trip |
| |
v. |
Plant Fires |
| |
w. |
Acts of Nature (e.g., tornado, flood, dam failure, earthquakes) |
| |
x. |
Irradiated Fuel Damage While Refueling |
| |
y. |
Abnormal Releases or Radioactivity |
| |
z. |
Intrusion of Demineralizer Resin Into Primary System (BWR
Plants) |
| 7. |
Procedures for Control of Radioactivity (For limiting materials
released to environment and limiting personnel exposure) |
| |
a. |
Liquid Radioactive Waste System |
| |
|
(1) |
Collection, Demineralizing, Filtering, Evaporating and Concentrating
and Neutralizing |
| |
|
(2) |
Sampling and Monitoring |
| |
|
(3) |
Discharging to Effluents |
| |
b. |
Solid Waste System |
| |
|
(1) |
Spent Resins and Filter Sludge Handling |
| |
|
(2) |
Baling Machine Operation |
| |
|
(3) |
Drum Handling and Storage |
| |
c. |
PWR Gaseous Effluent System |
| |
|
(1) |
Collection, Storage, and Discharge |
| |
|
(2) |
Sampling and Monitoring |
| |
|
(3) |
Air Ejector and Stack Monitoring |
| |
|
(4) |
Ventilation Air Monitoring |
| |
d. |
BWR Air Extraction, Offgas Treatment, and Other Gaseous Effluent
Systems |
| |
|
(1) |
Mechanical Vacuum Pump Operation |
| |
|
(2) |
Air Ejector Operation |
| |
|
(3) |
Packing Steam Exhauster Operation |
| |
|
(4) |
Sampling |
| |
|
(5) |
Air Ejector, Ventilation, and Stack Monitor |
| |
e. |
Radiation Protection Procedures |
| |
|
(1) |
Access Control to Radiation Areas Including a Radiation Work
Permit System |
| |
|
(2) |
Radiation Surveys |
| |
|
(3) |
Airborne Radioactivity Monitoring |
| |
|
(4) |
Contamination Control |
| |
|
(5) |
Respiration Protection |
| |
|
(6) |
Training in Radiation Protection |
| |
|
(7) |
Personnel Monitoring |
| |
|
(8) |
Bioassay Program |
| |
|
(9) |
Implementation of ALARA Program Area Radiation Monitoring
System Operation |
| |
g. |
Process Radiation Monitoring System Operation |
| |
h. |
Meteorological Monitoring |
| 8. |
Procedures for Control of Measuring and Test Equipment and
for Surveillance Tests, Procedures, and Calibrations |
| |
a. |
Procedures of a type appropriate to the circumstances should
be provided to ensure that tools, gauges. instruments. controls. and other
measuring and testing devices are properly controlled, calibrated and adjusted
at specified periods to maintain accuracy. Specific examples of such equipment
to be calibrated and jested are readout instruments. interlock permissive
and prohibit circuits. alarm devices, sensors, signal conditioners, controls,
protective circuits, and laboratory equipment. |
| |
b. |
Specific procedures for surveillance tests, inspections and
calibrations should be written (implementing procedures are required for
each surveillance test, inspection, or calibration listed in the technical
specifications): |
| |
|
(1) |
Pressurized Water Reactors |
| |
|
|
(a) |
Containment Leak-Rate Tests |
| |
|
|
(b) |
Containment Isolation Tests |
| |
|
|
(c) |
Containment Local Leak Detection Tests |
| |
|
|
(d) |
Containment Heat and Radioactivity Removal Systems Tests |
| |
|
|
(e) |
Containment Tendon Tests and Inspections |
| |
|
|
(f) |
Service Water System Functional Tests |
| |
|
|
(g) |
Main Steam Isolation Valve Tests |
| |
|
|
(h) |
Fire Protection System Functional Tests Boric Acid Tanks-Level Instrumentation
Calibrations |
| |
|
|
(i) |
Emergency Core Cooling System Tests |
| |
|
|
(k) |
Control Rod Operability and Scram Time Tests |
| |
|
|
(1) |
Reactor Protection System Tests and Calibrations |
| |
|
|
(m) |
Permissives-Tests and Calibrations |
| |
|
|
(n) |
Refueling System Circuit Tests |
| |
|
|
(o) |
Emergency Boration System Functional Tests |
| |
|
|
(p) |
DNB Checks and Incore-Excore Flux Monitor Correlations |
| |
|
|
(q) |
Emergency Power Tests |
| |
|
|
(r) |
Auxiliary Feedwater System Tests |
| |
|
|
(s) |
NSSS Pressurization and Leak Detection |
| |
|
|
(t) |
Inspection of Reactor Coolant System Pressure Boundary |
| |
|
|
(u) |
Inspection of Pipe Ranger Settings |
| |
|
|
(v) |
Control Rod Drive System Functional Tests |
| |
|
|
(w) |
Heat Balance-Flux Monitor Calibrations |
| |
|
|
(x) |
Pressurizer and Main Steam Safety Valve Tests |
| |
|
|
(y) |
Leak Detection Systems Tests |
| |
|
|
(z) |
Axial and Radial Flux Pattern Determinations |
| |
|
|
(aa) |
Area, Portable, and Airborne Radiation Mon- itor Calibrations |
| |
|
|
(bb) |
Process Radiation Monitor Calibrations |
| |
|
|
(cc) |
Environmental Monitor Calibrations |
| |
|
|
(dd) |
Safety Valve Tests |
| |
|
|
(ee) |
Turbine Overspeed Trip Tests |
| |
|
|
(ff) |
Water Storage Tanks-Level Instrumentation Calibration |
| |
|
(2) |
Boiling Water Reactors |
| |
|
|
(a) |
Containment Leak-Rate and Penetration Leak-Rate Tests |
| |
|
|
(b) |
Containment Isolation Tests |
| |
|
|
(c) |
Containment Vacuum Relief Valve Tests |
| |
|
|
(d) |
Containment Spray System Tests |
| |
|
|
(e) |
Standby Gas Treatment System Tests (including filter tests) |
| |
|
|
(f) |
Service Water System Functional Tests |
| |
|
|
(g) |
Main Stream Isolation Valve Tests |
| |
|
|
(h) |
Fire Protection System Functional Tests |
| |
|
|
(i) |
Nitrogen Inerting System Tests |
| |
|
|
(j) |
Emergency Core Cooling System Tests |
| |
|
|
(k) |
Control Rod Operability and Scram Time Tests |
| |
|
|
(l) |
Reactor Protection System Tests and Calibrations |
| |
|
|
(m) |
Rod Blocks-Tests and Calibrations |
| |
|
|
(n) |
Refueling System Circuit Tests |
| |
|
|
(o) |
Liquid Poison System Tests |
| |
|
|
(p) |
Minimum Critical Heat Flux Checks and Incore Flux Monitor Calibrations |
| |
|
|
(q) |
Emergency Power Tests |
| |
|
|
(r) |
Isolation Condenser or RCIC Tests |
| |
|
|
(s) |
NSSS Pressurization and Leak Detection |
| |
|
|
(t) |
Inspection of Reactor Coolant System Pressure Boundary |
| |
|
|
(u) |
Inspection of Pipe Hanger Settings |
| |
|
|
(v) |
Control Rod Drive System Functional Tests |
| |
|
|
(w) |
Heat Balance |
| |
|
|
(x) |
Autoblowdown System Tests |
| |
|
|
(y) |
Leak Detection System Tests |
| |
|
|
(z) |
Axial and Radial Flux Pattern Determinations |
| |
|
|
(aa) |
Area, Portable, and Airborne Radiation Monitor Calibrations |
| |
|
|
(bb) |
Process Radiation Monitor Calibrations |
| |
|
|
(cc) |
Environmental Monitor Calibrations |
| |
|
|
(dd) |
Safety Valve Tests |
| |
|
|
(ee) |
Turbine Overspeed Trip Test |
| |
|
|
(ff) |
Water Storage Tanks-Le vel Instrumentation Calibrations |
| |
|
|
(gg) |
Reactor Building Inleakage Tests |
| 9. |
Procedures for Performing Maintenance |
| |
a. |
Maintenance that can affect the performance of safety-related
equipment should be properly preplanned and performed in accordance with
written procedures, documented instructions, or drawings appropriate to
the circumstances. Skills normally possessed by qualified maintenance personnel
may not require detailed step-by-step delineation in a procedure. The following
types of activities are among those that may no! require detailed step-by-step
written procedures: |
| |
|
(1) |
Gasket Replacement |
| |
|
(2) |
Trouble-Shooting Electrical Circuits |
| |
|
(3) |
Changing Chart or Drive Speed Gears or Slide Wires on Recorders |
| |
b. |
Preventive maintenance schedules should be developed to specify
lubrication schedules, inspections of equipment. replacement of such items
as filters and strainers, and inspection or replacement of pans that have
a specific lifetime such as wear rings. |
| |
c. |
Procedures for the repair or replacement of equipment should
be prepared prior to beginning work. Such procedures for major equipment
that is expected to be repaired or replaced during the life of the plant
should preferably be written early in plant life. The following are examples
of such procedures for major equipment: |
| |
|
(1) |
Repair of PWR Steam Generator Tubes |
| |
|
(2) |
Replacement and Repair of Control Rod Drives |
| |
|
(3) |
Replacement of Recirculation Pump Seals |
| |
|
(4) |
Replacement of Important Strainers and Filters |
| |
|
(5) |
Repair or Replacement of Safety Valves |
| |
|
(6) |
Repair of Incore Flux Monitoring System |
| |
|
(7) |
Replacement of Neutron Detectors |
| |
d. |
Procedures that could be categorized either as maintenance
or operating procedures should be developed for the following activities.
Instructions for these activities may be included in Systems procedures. |
| |
|
(1) |
Exercise of equipment that is normally idle but that must
operate when required |
| |
|
(2) |
Draining and Refilling Heat Exchangers |
| |
|
(3) |
Draining and Refilling Recirculation Loop |
| |
|
(4) |
Draining and Refilling the Reactor Vessel |
| |
|
(5) |
Draining and Refilling Steam Generators |
| |
|
(6) |
Removal of Reactor Head |
| |
|
(7) |
Disconnection and Reconnection of Wiring Penetrating Reactor
Vessel Head |
| |
|
(8) |
Demineralize Resin Regeneration or Replacement |
| |
e. |
General procedures for the control of maintenance, repair,
replacement, and modification work should be prepared before reactor operation
is begun. These procedures should include information on areas such as the
following: |
| |
|
(1) |
Method for obtaining permission and clearance for operation
personnel to work and for logging such work and |
| |
|
(2) |
Factors to be taken into account, including the necessity
for minimizing radiation exposure to workmen, in preparing the detailed
work procedures. |
| 10. |
Chemical and Radiochemical Control Procedures |
| |
Chemical and radiochemical control procedures should be written
to prescribe the nature and frequency of sampling and analyses, the instructions
maintaining water quality within prescribed limits, and the limitations
on concentrations of agents that may cause corrosive attack or fouling of
heat-transfer surfaces or that may become sources of radiation hazards due
to activation. These procedures should specify laboratory instructions and
calibration of laboratory equipment. Extreme importance must be placed on
laboratory procedures used to determine concentration and species of radioactivity
in liquids and gases prior to release, including sampling, validity of calibration
techniques, and adequacy of analyses. |