| Table I.6, Calculational Method, Part 1---Total Hourly and Annual Dose Received from Gauge 1, 2, and 3 | |||||
| Step No. | Description | Gauge 1 | Gauge 2 | Gauge 3 | Sum |
|---|---|---|---|---|---|
| 7 | TOTAL HOURLY DOSE RECEIVED from Step 5 of Tables I-3, I-4, and I-5, in mrem in an hour | 0.031 | 0.056 | 0.08 | 0.031 + 0.056 + 0.08 = 0.167 |
| 8 | TOTAL ANNUAL DOSE RECEIVED from Step 6 of Tables I-3, I-4, and I-5, in mrem in a year | 272 | 491 | 701 | 272 + 491 + 701 = 1464 |
| NOTE: The Sum in Step 7 demonstrates compliance with the 2 mrem in any one hour limit. Reevaluate if assumptions change. If the Sum in Step 8 exceeds 100 mrem/yr, proceed to Part 2 of the calculational method. | |||||