United States Nuclear Regulatory Commission - Protecting People and the Environment
Home > NRC Library > Document Collections > NUREG-Series Publications > Staff Reports > NUREG-0933, Main Report with Supplements 1–34 > Section 2. Task Action Plan Items > Item A-39: Determination of Safety Relief Valve Pool Dynamic Loads and Temperature Limits (Rev. 1)

Resolution of Generic Safety Issues: Item A-39: Determination of Safety Relief Valve Pool Dynamic Loads and Temperature Limits (Rev. 1) (Rev. 3) ( NUREG-0933, Main Report with Supplements 1–34 )

DESCRIPTION

Operation of BWR primary system pressure relief valves can result in hydrodynamic loads on the suppression pool retaining structures or those structures located within the pool. These loads result from initial vent clearing of relief valve piping and steam quenching due to high local pool temperatures. The item addresses GE MARK I, II, and III containments and was originally identified in NUREG-03712 but was later determined to be a USI.

CONCLUSION

This USI was RESOLVED60 with the issuance of SRP11 Section 6.2.1.1.C. NUREG-0763,748 NUREG-0783,734 and NUREG-0802749 were also issued for Mark I, II, and III containments, respectively.