United States Nuclear Regulatory Commission - Protecting People and the Environment

Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition — Site Characteristics and Site Parameters (NUREG-0800, Chapter 2)

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

Section Title Rev. Date Updated
2.0 Site Characteristics and Site Parameters Initial Issuance 03/2007
2.1.1 Site Location and Description Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 07/1978
Rev. 0 11/1975
2.1.2 Exclusion Area Authority and Control Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 12/1978
Rev. 0 11/1975
2.1.3 Population Distribution Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 12/1978
Rev. 0 11/1975
2.2.1 - 2.2.2 Identification of Potential Hazards in Site Vicinity Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 07/1978
Rev. 0 11/1975
2.2.3 Evaluation of Potential Accidents Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 12/1978
Rev. 0 11/1975
2.3.1 Regional Climatology Rev. 3 03/2007
Draft Rev. 3 01/2006
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 04/1978
Rev. 0 11/1975
2.3.2 Local Meteorology Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 04/1978
Rev. 0 11/1975
2.3.3 Onsite Meteorological Measurements Programs Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 05/1978
Rev. 0 11/1975
2.3.4 Shortterm Dispersion Estimates for Accident Releases Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 07/1981
Rev. 0 11/1975
2.3.5 Long-Term Atmospheric Dispersion Estimates for Routine Releases Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 05/1978
Rev. 0 11/1975
2.4.1 Hydrologic Description Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.2 Floods Rev. 4 03/2007
Draft Rev. 4 06/1996
Rev. 3 04/1989
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.3 Probable Maximum Flood (PMF) on Streams and Rivers Rev. 4 03/2007
Draft Rev. 4 06/1996
Rev. 3 04/1989
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.4 Potential Dam Failures Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.5 Probable Maximum Surge and Seiche Flooding Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.6 Probable Maximum Tsunami Hazards Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.7 Ice Effects Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 05/1978
Rev. 0 11/1975
2.4.8 Cooling Water Canals and Reservoirs Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.9 Channel Diversions Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.10 Flooding Protection Requirements Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 05/1978
Rev. 0 11/1975
2.4.11 Low Water Considerations Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 05/1978
Rev. 0 11/1975
2.4.12 Groundwater Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 07/1978
Rev. 0 11/1975
2.4.13 Accidental Releases of Radioactive Liquid Effluents in Ground and Surface Waters Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.4.14 Technical Specifications and Emergency Operation Requirements Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 06/1978
Rev. 0 11/1975
2.5.1 Basic Geologic and Seismic Information Rev. 4 03/2007
Rev. 3 03/1997
Rev. 2 07/1981
Rev. 1 11/1978
Rev. 0 11/1975
2.5.2 Vibratory Ground Motion Rev. 4 03/2007
Rev. 3 03/1997
2nd Proposed Rev. 3 02/1995
Rev. 2 08/1989
Rev. 1 07/1981
Rev. 0 11/1975
2.5.3 Surface Faulting Rev. 4 03/2007
Rev. 3 03/1997
Rev. 2 07/1981
Rev. 1 11/1978
Rev. 0 11/1975
2.5.4 Stability of Subsurface Materials and Foundations Rev. 4 05/2010
Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 11/1978
Rev. 0 11/1975
2.5.5 Stability of Slopes Rev. 4 05/2010
Rev. 3 03/2007
Draft Rev. 3 06/1996
Rev. 2 07/1981
Rev. 1 11/1978
Rev. 0 11/1975

 

 

 

 

Page Last Reviewed/Updated Friday, December 09, 2011