Reliability Study: Combustion Engineering Reactor Protection System, 1984–1998 (NUREG/CR-5500, INEL/EXT-97-00740, Volume 10)
On this page:
Download complete document
This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.
- NUREG/CR-5500, Volume. 10
Publication Information
Manuscript Completed: November 2001
Date Published: November 2001
Prepared by:
Thomas E. Wierman, Scott T. Beck, Michael B. Calley
Steven A. Eide, Cindy D. Gentillon, William E. Kohn
Risk & Reliability Assessment Department
Idaho National Engineering and Environmental Laboratory
P.O. Box 1625
Idaho Falls, Idaho 83415-3850
Prepared for:
Division of Risk Analysis & Applications
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
NRC Job Code Y6214
Abstract
This report documents an analysis of the safety-related performance of the reactor protection system (RPS) at U.S. Combustion Engineering commercial reactors during the period 1984 through 1998. The analysis is based on the four variations of Combustion Engineering reactor protection system designs. RPS-operational data were collected for all U.S. Combustion Engineering commercial reactors from the Nuclear Plant Reliability Data System and Licensee Event Reports. A risk-based analysis was performed on the data to estimate the observed unavailability of the RPS, based on fault tree models of the systems. An engineering analysis of trends and patterns was also performed on the data to provide additional insights into RPS performance. RPS unavailability results obtained from the data were compared with existing unavailability estimates from Individual Plant Examinations and other reports.