Development of a Computer Tool for In-Depth Analysis and Post Processing of the RELAP5 Thermal Hydraulic Code (NUREG/IA-0253)
On this page:
Download complete document
This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.
Publication Information
Manuscript Completed: April 2003
Date Published: April 2011
Prepared by:
Roberto Herrero Santos* and José María Izquierdo Rocha*
*Consejo de Seguridad Nuclear
Justo Dorado, 11
28040 Madrid – Spain
A. Calvo, NRC Project Manager
Prepared for:
Division of Systems Analysis
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
Under the International Code Assessment and Maintenance Program (CAMP)
Published by:
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
The Spanish Nuclear Safety Council (CSN) has sponsored the development of a computer tool for the error diagnosis and interpretation of the results obtained with the code RELAP5/MOD3.2.
The report describes the tests used to check the consistency of the results and illustrates some application examples that point out some defficiencies in the code.