Data Base on the Behavior of High Burnup Fuel Rods with Zr-1%Nb Cladding and U0 2 Fuel (VVER Type) under Reactivity Accident Conditions: Review of Research Program and Analysis of Results (NUREG/IA-0156, Volume 1, IPSN 99/08-1, NSI RRC KI-2179)
On this page:
Download complete document
This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.
Publication Information
Manuscript Completed: December 1998
Date Published: July 1999
Prepared by:
L. Yegorova
Nuclear Safety Institute of Russian Research Centre, "Kurchatov Institute"
Kurchatov Square 1
Moscow 123182, Russia
Prepared for:
U.S. Nuclear Regulatory Commission
Institute for Protection and Nuclear Safety (France)
Ministry of Science and Technologies of Russian Federation
Published by:
Division of Systems Analysis and Regulatory Effectiveness
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001
Abstract
The present report contains a data base used for analyzing the behavior of three types of VVER fuel rods (fresh fuel rods; fuel rods with fresh fuel and irradiated cladding; high burnup fuel rods) which have been tested in the Impulse Graphite Reactor (IGR) under reactivity accident conditions. The basic test parameters are as follows:
- capsule tests with stagnant water or air coolant under ambient conditions;
- pressurized fuel rods;
- fuel burnup: 0 and 48 MWd/kg U;
- pulse width: about 700 Ms.
The presented data base includes the results of reactor tests of 25 fuel rods as well as results of pre- and posttest examinations of fuel rods, computer simulations of fuel rod behavior under test conditions; in addition, the report presents the results of special out-of-pile tests carried out to measure mechanical properties of Zr-1%Nb cladding.
The report consists of three volumes, each volume contains the following information:
| Volume 1: | Brief description of the test program, testing and analytical techniques and summary of results; |
| Volume 2: | Description and validation of procedures used to obtain the data base. Summarization of test results as supported by mechanical properties of Zr-1%Nb cladding; |
| Volume 3: | Data base consisting of:
|