Assessment of RELAP5/MOD2, Cycle 36.04 Against LOFT Small Break Experiment L3-5 (NUREG/IA-0037)
On this page:
Download complete document
This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.
Publication Information
Date Published: March 1992
Prepared by:
J. Eriksson
Swedish Nuclear Power Inspectorate
S-61182 Nykoping
Sweden
Prepared as part of:
The Agreement on Research Participation and Technical Exchange
under the International Thermal-Hydraulic Code Assessment
and Application Program (ICAP)
Published by:
Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, DC 20555
Abstract
The LOFT small break experiment L3-5 has been analyzed using the RELAP5/MOD2 code. The code version used, Cycle 36.04, is a frozen version of the code.
Three calculations were carried out in order to study the sensitivity to changes of steam generator modelling and of core bypass flow. The differences between the calculations and the experiment have been quantified over intervals in real time for a number of variables available from the experiment.