United States Nuclear Regulatory Commission - Protecting People and the Environment

Assessment of TRAC-PD2 Using SUPER CANNON and HDR Experimental Data (NUREG/IA-0001)

On this page:

Download complete document

This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.

Publication Information

Date Published: August 1986

Prepared by:
U. Neumann

Kraftwerk Union
Hammerbacherstr. 12+ 14
Postfach 3220
8520 Erlangen, The Federal Republic of Germany

Office of Nuclear Regulatory Research
U.S. Nuclear Regulatory Commission
Washington, D.C. 20555

Availability Notice

Abstract

This report assesses the predictive capabilities of the Transient Reactor Analysis Code (TRAC-PD2) using data from the SUPER CANON and HEISS DAMPF REACTOR (HDR) experimental facilities. The report is divided into three parts. Part I is the TRAC-PD2 assessment using SUPER CANON data. Part II is the TRAC-PD2 assessment using HDR data. Part III provides recommendations for the user using the combined assessment results. In general, it is shown that the TRAC-PD2 predictions were in good agreement with the actual test pressures and and mass flow rates for both these tests. TRAC-PD2 provided considerably better results than TRAC-P1A. This was particularly true with regard to sound velocity predictions which play a significant role whenever the speed of pressure relief waves must be determined.

Page Last Reviewed/Updated Thursday, March 29, 2012