Home > NRC Library > Document Collections > General Communications > Information Notices > 1988 > IN 88-19
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF NUCLEAR REACTOR REGULATION
WASHINGTON, D.C. 20555
April 26, 1988
Information Notice No. 88-19: QUESTIONABLE CERTIFICATION OF
CLASS 1E COMPONENTS
Addressees:
All holders of operating licenses or construction permits for nuclear power
reactors.
Purpose:
This information notice is being provided to alert addressees to a possible
problem with the certification of Class 1E components furnished by Planned
Maintenance Systems (PMS) of Mt. Vernon, Illinois. It is expected that
recipients will review the information for applicability to their facilities
and consider actions, as appropriate, to avoid similar problems. However,
suggestions contained in this information notice do not constitute NRC
requirements; therefore, no specific action or written response is required.
Description of Circumstances:
On April 1, 1988, Wolf Creek Nuclear Operating Corporation (WCNOC) submitted a
written 10 CFR Part 21 Notification to NRC Region IV concerning 60 Class 1E
fuses that had been procured from PMS. One of the requirements of the
purchase order (PO) issued to PMS was that the PO items were to be supplied in
accordance with the requirements of a specific fuse qualification
specification for Class 1E equipment. This specification contained detailed
requirements including materials, environmental qualification, seismic
qualification, and inspection/ test requirements. The PMS Certificate of
Compliance supplied with the order certified that all of the procurement
document requirements had been met and no deviations from the requirements had
been identified.
The fuses were placed on hold by WCNOC because a required Quality Department
surveillance had not been performed. A subsequent WCNOC surveillance revealed
that the records in PMS's possession did not support the statement on the PMS
Certificate of Compliance that all PO requirements had been met.
Qualification specification requirements were not covered by PMS quality
assurance records with respect to information on environmental qualification,
radiation levels, and seismic qualification. In addition, it could not be
established that a required continuity/resistance check of each fuse had been
performed before the fuses were shipped.
8804220217
. IN 88-19
April 26, 1988
Page 2 of 2
Discussion:
The WCNOC 10 CFR Part 21 notification has brought into question the validity
of the Certificate of Compliance issued by PMS for Class 1E fuses that they
supplied. Accordingly, licensees may wish to review Class 1E component pro-
curements from this vendor to ensure that appropriate bases exist for the use
of the components.
No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the technical
contact listed below or the Regional Administrator of the appropriate regional
office.
Charles E. Rossi, Director
Division of Operational Events Assessment
Office of Nuclear Reactor Regulation
Technical Contact: Joseph J. Petrosino, NRR
(301) 492-0979
Attachment: List of Recently Issued NRC Information Notices
. Attachment
IN 88-19
April 26, 1988
Page 1 of 1
LIST OF RECENTLY ISSUED
NRC INFORMATION NOTICES
_____________________________________________________________________________
Information Date of
Notice No._____Subject_______________________Issuance_______Issued to________
88-18 Malfunction of Lockbox on 4/25/88 All NRC licensees
Radiography Device authorized to
manufacture,
distribute, and/or
operate radio-
graphic exposure
devices.
88-17 Summary of Responses to NRC 4/22/88 All holders of OLs
Bulletin 87-01, "Thinning of or CPs for nuclear
Pipe Walls in Nuclear Power power reactors.
Plants"
88-16 Identifying Waste Generators 4/22/88 Radioactive waste
in Shipments of Low-Level collection and
Waste to Land Disposal service company
Facilities licensees handling
prepackaged waste,
and licensees
operating
low-level waste
disposal
facilities.
88-15 Availability of U.S. Food 4/18/88 Medical, Academic,
and Drug Administration and Commercial
(FDA)-Approved Potassium licensees who
Iodide for Use in Emergencies possess
Involving Radioactive Iodine radioactive
iodine.
88-14 Potential Problems with 4/18/88 All holders of OLs
Electrical Relays or CPs for nuclear
power reactors.
88-13 Water Hammer and Possible 4/18/88 All holders of OLs
Piping Damage Caused by or CPs for nuclear
Misapplication of Kerotest power reactors.
Packless Metal Diaphragm
Globe Valves
88-12 Overgreasing of Electric 4/12/88 All holders of OLs
Motor Bearings or CPs for nuclear
power reactors.
_____________________________________________________________________________
OL = Operating License
CP = Construction Permit
Page Last Reviewed/Updated Thursday, March 29, 2012