Implementation of TMI Action ITEM II.K.3.5, "Automatic Trip of Reactor Coolant Pumps" (Generic Letter No. 86-05)
UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D. C. 20555
May 29, 1986
TO ALL APPLICANTS AND LICENSEES WITH BABCOCK AND WILCOX (B&W) DESIGNED
NUCLEAR STEAM SUPPLY SYSTEMS (NSSSs)
SUBJECT: IMPLEMENTATION OF TMI ACTION ITEM II.K.3.5, "AUTOMATIC TRIP OF
REACTOR COOLANT PUMPS" (GENERIC LETTER NO. 86-05)
Gentlemen:
The purpose of this letter is to inform you of (1) the staff's conclusions
regarding the B&W Owners Group (BWOG) submittals on reactor coolant pump
trip in response to Generic Letters 83-10e and f, and (2) provide guidance
concerning implementation of the reactor coolant pump trip criterion. Our
Safety Evaluation (SE) on this subject is enclosed for your use.
With regard to the BWOG submittals referenced in Section V of the enclosed
SE, we conclude that the methods employed by the BWOG to justify manual
reactor coolant pump (RCP) trip are consistent with the guidelines and
criteria provided in Generic Letters 83-10e and f. The approved B&W Small
Break LOCA Evaluation Model was used to demonstrate compliance with 10 CFR
50.46 and Appendix K to 10 CFR Part 50.
We have determined that the information provided by the BWOG in support of
the loss-of-subcooling RCP trip criterion is acceptable. The generic
information presented by the BWOG, however, does not address plant specific
concerns about instrumentation uncertainties, potential reactor coolant pump
problems and operator training and procedures as requested in Generic Letter
83-10. This information, contained in Section IV of the SE, is now being
requested to assess implementation of the RCP trip criterion.
Accordingly, for those applicants and licensees who choose to endorse the
BWOG methodology, we request that operating reactor licensees implement the
RCP trip criterion based upon the BWOG methodology. Schedules for submittal
of information requested in Section IV of the SE (refer to Appendix A for
considerations associated with Generic Letters 83-10e and f) should be
developed with your individual project managers within 45 days from receipt
of this letter. The requested information does not constitute a new
requirement but only identifies information specified in Generic Letters
83-10e and f which has not been provided under the BWOG generic program. In
@ the event that licensees decide not to trip the RCP (an option provided
for in Generic Letters 83-10e and f), they should respond to the questions
in Section IV of the SE and refer to Appendix B of the SE. Applicants should
provide toe appropriate response to the extent that this information is
known at this time.
Those applicants and licensees who choose not to endorse the BWOG
methodology should submit a schedule for submittal of plant specific RCP
trip criteria or justification for non-trip of RCPs within 45 days of
receipt of this letter.
- 2 -
This request for information was approved by the Office of Management and
Budget under clearance number 3150-0011 which expires September 30, 1986.
Comments on burden and duplication may be directed to the Office of
Management and Budget, Reports Management, Room 3208, New Executive Office
Building, Washington, D.C. 20503.
Our review of your submittal of information in response to this letter is
not subject to fees under the provisions of 10 CFR 170. However, should you,
as part of your response or in a subsequent submittal, include an
application for license amendment or other action requiring NRC approval, it
is subject to the fee requirements of 10 CFR 170 with remittal of an
application fee of $150 per application (Sections 170.12(c) and 170.21) and
subsequent semiannual payments until the review is completed or the ceiling
in Section 170.21 is reached.
If you believe further clarification regarding this issue is necessary or
desirable, please contact Mr. R. Lobel (301 492-9475).
Sincerely,
Frank J. Miraglia, Director
Division of PWR Licensing-B
Enclosure:
Safety Evaluation