UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D.C. 20555
April 15, 1982
TO ALL PRESSURIZED WATER REACTOR PLANT LICENSEES AND APPLICANTS
Gentlemen:
SUBJECT: TRANSMITTAL OF NUREG-0909 RELATIVE TO THE GINNA TUBE RUPTURE
(Generic Letter No. 82-08)
On January 25, 1982, the R. E. Ginna Nuclear Power Plant experienced a
rupture of a steam generator tube. Shortly after the event, Chairman
Palladino directed that a task force be established to gather and report on
the factual information surrounding the event.
The task force has now completed its investigation and has documented the
factual information and their findings associated with the event (See
Enclosed NUREG-0909). You should review the information for applicability to
your facility.
In addition, you should ensure that the information in NUREG-0909 is made
available to your plant staff as part of your training program under TMI
Action Plan Item I.C.5, Feedback of Operating Experience to Plant Staff.
Sincerely,
Darrell G. Eisenhut, Director
Division of Licensing
Office of Nuclear Reactor Regulation
Enclosure:
NUREG-0909
8204160155
Page Last Reviewed/Updated Tuesday, March 09, 2021