Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Beaver Valley 1 | 100 | | | | |
Beaver Valley 2 | 100 | | | | |
Calvert Cliffs 1 | 100 | | HIGH SYSTEM VOLTAGE ACTION | * | |
Calvert Cliffs 2 | 100 | | HIGH SYSTEM VOLTAGE ACTION | * | |
FitzPatrick | 100 | | | | |
Ginna | 100 | | | | |
Hope Creek 1 | 100 | | | | |
Indian Point 2 | 100 | | 13.8 KV LINE 33332LM OOS | | |
Indian Point 3 | 100 | | 13.8 KV LINE 33332LM OOS | | |
Limerick 1 | 100 | | | | |
Limerick 2 | 0 | 03/24/2013 | REFUELING OUTAGE | | |
Millstone 2 | 100 | | | | |
Millstone 3 | 100 | | | | |
Nine Mile Point 1 | 98 | | COASTDOWN TO REFUELING OUTAGE | | |
Nine Mile Point 2 | 100 | | | | |
Oyster Creek | 100 | | | | |
Peach Bottom 2 | 100 | | | | |
Peach Bottom 3 | 100 | | | | |
Pilgrim 1 | 86 | | POWER LIMITED TO MONITOR AN SRV TAILPIPE TEMPERATURE LINE 355 OOS FOR PM | | |
Salem 1 | 99 | | 500 kV LINE OOS FOR MAINTENANCE | | |
Salem 2 | 99 | | 500 kV LINE OOS FOR MAINTENANCE | | |
Seabrook 1 | 100 | | | | |
Susquehanna 1 | 99 | | LIMITED BY GENERATOR CAPABILITY CURVE - VOLTAGE REGULATOR IN MANUAL - OUTPUT LIMITED TO 1340 MWE BY GRID OPERATOR - HIGH SYSTEM VOLTAGE ACTION | | |
Susquehanna 2 | 100 | | LIMITED BY GENERATOR CAPABILITY CURVE - OUTPUT LIMITED TO 1340 MWE BY GRID OPERATOR - HIGH SYSTEM VOLTAGE ACTION | * | |
Three Mile Island 1 | 100 | | HIGH SYSTEM VOLTAGE ACTION | | |
Vermont Yankee | 98 | | INCREASING POWER | * | |
Region 2
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Browns Ferry 1 | 100 | | | | |
Browns Ferry 2 | 0 | 03/14/2013 | REFUELING OUTAGE | | |
Browns Ferry 3 | 100 | | | | |
Brunswick 1 | 100 | | | | |
Brunswick 2 | 0 | 03/02/2013 | REFUELING OUTAGE | | |
Catawba 1 | 100 | | | | |
Catawba 2 | 100 | | | | |
Crystal River 3 | 0 | 02/03/2013 | DEFUELED | | |
Farley 1 | 100 | | | | |
Farley 2 | 72 | | COASTDOWN TO REFUELING OUTAGE | | |
Harris 1 | 100 | | | | |
Hatch 1 | 100 | | | | |
Hatch 2 | 100 | | | | |
McGuire 1 | 0 | 03/16/2013 | REFUELING OUTAGE - CORE RELOAD COMPLETE | * | |
McGuire 2 | 100 | | | | |
North Anna 1 | 100 | | | | |
North Anna 2 | 0 | 04/06/2013 | REFUELING OUTAGE | * | |
Oconee 1 | 100 | | | | |
Oconee 2 | 100 | | | | |
Oconee 3 | 100 | | | | |
Robinson 2 | 100 | | | | |
Saint Lucie 1 | 100 | | | | |
Saint Lucie 2 | 100 | | | | |
Sequoyah 1 | 100 | | | | |
Sequoyah 2 | 100 | | | | |
Summer | 100 | | | | |
Surry 1 | 100 | | HIGH SYSTEM VOLTAGE ACTION | * | |
Surry 2 | 100 | | HIGH SYSTEM VOLTAGE ACTION | * | |
Turkey Point 3 | 95 | | REDUCED POWER DUE TO EXCESSIVE HIGH STEAM FLOW ALARMS | | |
Turkey Point 4 | 2 | | PERFORMING EXTENDED POWER UPRATE TESTING | * | |
Vogtle 1 | 100 | | | | |
Vogtle 2 | 100 | | | | |
Watts Bar 1 | 100 | | | | |
Region 3
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Braidwood 1 | 100 | | | | |
Braidwood 2 | 100 | | | | |
Byron 1 | 100 | | | | |
Byron 2 | 0 | 04/07/2013 | REFUELING OUTAGE | * | |
Clinton | 97 | | 100% ELECTRICAL CAPABILITY | | |
D.C. Cook 1 | 0 | 03/26/2013 | REFUELING OUTAGE - HIGH VOLTAGE ACTION | * | |
D.C. Cook 2 | 100 | | HIGH VOLTAGE ACTION | * | |
Davis-Besse | 100 | | | | |
Dresden 2 | 100 | | | | |
Dresden 3 | 100 | | | | |
Duane Arnold | 100 | | | | |
Fermi 2 | 65 | | MAIN FEEDPUMP REPAIRS IN PROGRESS | | |
Kewaunee | 100 | | | | |
La Salle 1 | 100 | | | | |
La Salle 2 | 100 | | | | |
Monticello | 0 | 03/01/2013 | REFUELING OUTAGE | | |
Palisades | 100 | | | | |
Perry 1 | 0 | 03/17/2013 | REFUELING OUTAGE | | |
Point Beach 1 | 0 | 03/17/2013 | REFUELING OUTAGE - CORE RELOAD COMPLETE | * | |
Point Beach 2 | 100 | | | | |
Prairie Island 1 | 100 | | | | |
Prairie Island 2 | 100 | | | | |
Quad Cities 1 | 11 | | PLACING TURBINE ON LINE | * | |
Quad Cities 2 | 100 | | | | |
Region 4
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Arkansas Nuclear 1 | 0 | 03/24/2013 | REFUELING OUTAGE | | |
Arkansas Nuclear 2 | 0 | 03/31/2013 | FORCED OUTAGE - SEE EVENT #48869 | | |
Callaway | 1 | | ENTERING REFUELING OUTAGE | * | |
Columbia Generating Station | 100 | | | | |
Comanche Peak 1 | 0 | 03/30/2013 | REFUELING OUTAGE | | |
Comanche Peak 2 | 100 | | | | |
Cooper | 100 | | | | |
Diablo Canyon 1 | 100 | | | * | |
Diablo Canyon 2 | 100 | | | * | |
Fort Calhoun | 0 | 04/09/2011 | REFUELING OUTAGE | | |
Grand Gulf 1 | 91 | | INCREASING POWER AFTER ROD PATTERN ADJUSTMENT | * | |
Palo Verde 1 | 0 | 03/30/2013 | REFUELING OUTAGE | | |
Palo Verde 2 | 100 | | | | |
Palo Verde 3 | 100 | | | | |
River Bend 1 | 100 | | | | |
San Onofre 2 | 0 | 01/09/2012 | REFUELING OUTAGE | | |
San Onofre 3 | 0 | 01/31/2012 | FORCED OUTAGE - S/G REPAIR | | |
South Texas 1 | 100 | | | | |
South Texas 2 | 0 | 01/08/2013 | FORCED OUTAGE | | |
Waterford 3 | 100 | | | | |
Wolf Creek 1 | 0 | 02/03/2013 | REFUELING OUTAGE | * | |