Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Beaver Valley 1 | 100 | | | | |
Beaver Valley 2 | 100 | | | | |
Calvert Cliffs 1 | 100 | | | | |
Calvert Cliffs 2 | 100 | | | | |
FitzPatrick | 100 | | AT 0400 ON 9DEC07; 1 OF 2 345 KV OUTPUT BREAKER OOS FOR PLANNED MAINTENANCE | * | |
Ginna | 100 | | | | |
Hope Creek 1 | 98 | | CROSS FLOW DATA ACQUISITION IN PROGRESS. | | |
Indian Point 2 | 100 | | | | |
Indian Point 3 | 100 | | | | |
Limerick 1 | 100 | | | | |
Limerick 2 | 100 | | | | |
Millstone 2 | 100 | | | | |
Millstone 3 | 100 | | | | |
Nine Mile Point 1 | 100 | | PERFORMING MAINTENANCE ON 345KV LINE (LINE 8, NOT COMMON TO UNIT 2) | | |
Nine Mile Point 2 | 95 | | DOWNPOWER TO TROUBLESHOOT ISSUES WITH MSR | * | |
Oyster Creek | 100 | | 4 RECIRC LOOP OPERATION, 'C' RECIRC PUMP SEAL FAILURE. | | |
Peach Bottom 2 | 100 | | | | |
Peach Bottom 3 | 100 | | | | |
Pilgrim 1 | 100 | | | | |
Salem 1 | 100 | | | | |
Salem 2 | 100 | | | | |
Seabrook 1 | 100 | | POWER REDUCTION THREAT DUE TO GRID WORK IN NEW YORK UNTIL JANUARY | | |
Susquehanna 1 | 100 | | | | |
Susquehanna 2 | 100 | | VOLTAGE REGULATOR IN MANUAL | | |
Three Mile Island 1 | 100 | | | | |
Vermont Yankee | 100 | | | | |
Region 2
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Browns Ferry 1 | 100 | | WESTPOINT LINE OOS | * | |
Browns Ferry 2 | 100 | | WESTPOINT LINE OOS | * | |
Browns Ferry 3 | 98 | | INCREASING POWER WESTPOINT LINE OOS | * | |
Brunswick 1 | 100 | | | | |
Brunswick 2 | 100 | | | | |
Catawba 1 | 100 | | | | |
Catawba 2 | 100 | | | | |
Crystal River 3 | 75 | | HOLDING POWER FOR PHYSICS TESTING | * | |
Farley 1 | 100 | | | | |
Farley 2 | 100 | | | | |
Harris 1 | 100 | | | | |
Hatch 1 | 100 | | | | |
Hatch 2 | 100 | | | | |
McGuire 1 | 99 | | DOWNPOWER IN PROGRESS TO 98% TO TROUBLESHOOT FEEDWATER PUMP CONTROLLER. FURTHER REDUCTION TO 90% - 95%, IF CARD REPLACEMENT IS NECESSARY. | * | |
McGuire 2 | 100 | | | | |
North Anna 1 | 100 | | | | |
North Anna 2 | 100 | | | | |
Oconee 1 | 100 | | | | |
Oconee 2 | 100 | | | | |
Oconee 3 | 0 | 10/26/2007 | FUEL RELOAD IN PROGRESS | | |
Robinson 2 | 100 | | | | |
Saint Lucie 1 | 100 | | | | |
Saint Lucie 2 | 0 | 09/30/2007 | REFUELING OUTAGE | | |
Sequoyah 1 | 100 | | | | |
Sequoyah 2 | 100 | | | | |
Summer | 100 | | | | |
Surry 1 | 100 | | | | |
Surry 2 | 100 | | | | |
Turkey Point 3 | 100 | | | | |
Turkey Point 4 | 100 | | | | |
Vogtle 1 | 97 | | 100% ELECTRICAL CAPABILITY | | |
Vogtle 2 | 98 | | 100% ELECTRICAL CAPABILITY | | |
Watts Bar 1 | 100 | | | | |
Region 3
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Braidwood 1 | 100 | | | | |
Braidwood 2 | 100 | | | | |
Byron 1 | 100 | | | | |
Byron 2 | 100 | | | | |
Clinton | 96 | | COASTDOWN TO REFUELING OUTAGE | | |
D.C. Cook 1 | 100 | | | | |
D.C. Cook 2 | 100 | | | | |
Davis-Besse | 100 | | | | |
Dresden 2 | 97 | | 100% ELECTRICAL CAPABILITY | | |
Dresden 3 | 99 | | 100% ELECTRICAL CAPABILITY | | |
Duane Arnold | 98 | | 100% ELECTRICAL CAPABILITY | | |
Fermi 2 | 100 | | | | |
Kewaunee | 100 | | | | |
La Salle 1 | 86 | | COASTDOWN TO REFUELING OUTAGE | * | |
La Salle 2 | 100 | | | | |
Monticello | 100 | | | | |
Palisades | 100 | | | | |
Perry 1 | 13 | | HOLDING FOR RCIC TESTING; WARMUP OF MAIN TURBINE | * | |
Point Beach 1 | 100 | | | | |
Point Beach 2 | 100 | | | | |
Prairie Island 1 | 100 | | | | |
Prairie Island 2 | 100 | | | | |
Quad Cities 1 | 97 | | 100% ELECTRICAL CAPABILITY | | |
Quad Cities 2 | 97 | | 100% ELECTRICAL CAPABILITY | * | |
Region 4
Unit | Power | Down | Reason or Comment | Change in report (*) | Number of Scrams (#) |
Arkansas Nuclear 1 | 100 | | | | |
Arkansas Nuclear 2 | 100 | | | | |
Callaway | 100 | | OFFSITE SOURCE 345 KV LINE (CAL BLAND 1) OOS UNTIL 09DEC07 | | |
Columbia Generating Station | 100 | | | | |
Comanche Peak 1 | 100 | | | | |
Comanche Peak 2 | 100 | | | | |
Cooper | 100 | | | | |
Diablo Canyon 1 | 100 | | | | |
Diablo Canyon 2 | 92 | | TROUBLESHOOTING MOISTURE SEPARATOR REHEATER STEAM LEAK | * | |
Fort Calhoun | 100 | | | | |
Grand Gulf 1 | 100 | | | | |
Palo Verde 1 | 99 | | INCREASING POWER | * | |
Palo Verde 2 | 100 | | | | |
Palo Verde 3 | 0 | 09/29/2007 | DEFUELED | | |
River Bend 1 | 83 | | INCREASING POWER | * | |
San Onofre 2 | 0 | 11/26/2007 | REFUELING OUTAGE. | * | |
San Onofre 3 | 99 | | | | |
South Texas 1 | 100 | | | | |
South Texas 2 | 100 | | | | |
Waterford 3 | 100 | | | | |
Wolf Creek 1 | 100 | | | | |
* - Power Reactor Status Report change within past 24 hours