Part 21 Report - 1998-490
LICENSEE: ENTEK IRD INTERNATIONAL CORP.
SITE: ENTEK IRD INTERNATIONAL CORP. EN NUMBER:34371
DOCKET: EVENT DATE: 06-09-98
RX TYPE: EVENT TIME: 00:00
VENDORS: NOTIFY DATE: 06-09-98
EMERGENCY CLASS: N/A REGION: 3 STATE: OH TIME: 13:48
OPS OFFICER: CHAUNCEY GOULD
10 CFR SECTION: CCCC 21.21 UNSPECIFIED PARAGRAPH
REPORT IN ACCORDANCE WITH 10 CFR PART 21
ENTEK IRD INTERNATIONAL, CORP., IS THE SUPPLIER OF CALIBRATION
SERVICES FOR NIST TRACEABILITY OF VIBRATION MEASUREMENTS FOR
PORTABLE VIBRATION MEASUREMENT EQUIPMENT.
PRIOR TO A MERGER BETWEEN ENTEK SCIENTIFIC AND IRD MECHANALYSIS,
INC., IN 1996, AUDITS WERE PERFORMED BY PACIFIC GAS & ELECTRIC
AGAINST 10 CFR PART 50, APPENDIX B, AND THERE WAS A QUESTION OF
THE ACCURACY OF THE CALIBRATION CERTIFICATES BEING PROVIDED BY
IRD MECHANALYSIS, INC. IRD MECHANALYSIS, INC., HAD BEEN
PROVIDING CALIBRATION CERTIFICATES INDICATING ACCURACY FOR
TRANSDUCERS CALIBRATED ON ITS UNHOLTZ-DICKIE SHAKER TABLES WITH A
4:1 ACCURACY RATIO WHEN IT ACTUALLY HAD A 3.125:1 ACCURACY RATIO.
THE COMPANY IS ADVISING LICENSEES TO EVALUATE THE IMPACT OF A
CHANGE FROM A 4:1 ACCURACY RATIO TO A 3.125:1 ACCURACY RATIO.
(REFER TO THE HOO LOG FOR A CONTACT TELEPHONE NUMBER.)