Event Number: 50593
Facility: QUAD CITIES
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: RICHARD BOSTON
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 11/04/2014
Notification Time: 18:00 [ET]
Event Date: 11/04/2014
Event Time: 11:00 [CST]
Last Update Date: 11/04/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
DAVE PASSEHL (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
UNIT 2 HIGH PRESSURE COOLANT INJECTION (HPCI) INOPERABLE

"On November 4, 2014, at 1100 [CST], LS 2-2365 (HPCI Turbine Inlet Drain Pot Level Switch) was determined to be inoperable during planned testing. HPCI was inoperable (for the planned testing) at the time of discovery. The function of LS 2-2365 is to detect a failure of the HPCI steam trap (i.e., outlet of the HPCI inlet drain pot) by providing a control room alarm and opening an alternate drain path.

"HPCl is a single train safety system and this notification is being made in accordance with 10CFR50.72 (b)(3)(v)(D).

"The NRC Resident Inspector has been notified."


Agreement State
Event Number: 50620
Rep Org: NEW YORK STATE DEPT. OF HEALTH
Licensee: ROSWELL PARK CANCER INSTITUTE
Region: 1
City: BUFFALO   State: NY
County:
License #: NYS #2923
Agreement: Y
Docket:
NRC Notified By: ROBERT SNYDER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 11/18/2014
Notification Time: 09:32 [ET]
Event Date: 11/04/2014
Event Time: 00:00 [EST]
Last Update Date: 11/18/2014
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
TODD JACKSON (R1DO)
NMSS EVENTS NOTIFICA (EMAI)
Event Text
AGREEMENT STATE REPORT - I-125 SEED RETRIEVED FROM PATIENT AND THEN LOST

The following information was obtained from the State of New York via facsimile:

"A radioactive source or I-125 seed used for localization in breast surgery was misplaced by the Pathology Department at Roswell Park Cancer Institute (DOH# 2923). This event occurred on Thursday, October 9, 2014 and the source was officially determined to be lost on November 4, 2014.

"Two breast localization seeds (I-125) were not extracted from a specimen on October 9, 2014 by a Clinical Pathology Fellow. The Pathology department did, however, receive written documentation that the seeds were removed from the patient and they were sent with the specimen to the Pathology Department. The seeds were not returned to Nuclear Medicine per Institute Policy.

"An extensive search and survey was conducted of Pathology, Nuclear Medicine and Environmental Services areas. One of the two seeds was discovered in trash removed from the Pathology department. Further search and surveys of these areas were repeated but to no avail. Trash and regulated medical waste were surveyed and inspected. Over the course of the next few weeks, Radiation Safety surveyed and explored all radioactive waste in an effort to locate the lost source. Aforementioned search and surveys were again conducted without discovery of the missing seed. It was believed that the missing source would eventually be located in Institute trash or more likely Institute radioactive waste.

"All Institute trash and waste is surveyed for radioactive material. The radioactive waste may be stored in various short and long-term storage locations. Unfortunately, the seed was never found and officially declared lost on November 4, 2014.

"Corrective Action and Recommendations:
1. The incident was reviewed and discussed with pertinent Pathology staff. A training oversight was discovered and Pathology Department Fellows are now trained to anticipate radioactive seeds in breast surgical specimens and to remove them prior to surgical specimen evaluation. (Required Corrective Action)
2. Radiation Safety and Environmental Services have emphasized the importance of monitoring all trash and regulated medical waste during the annual in-service conducted on August 6, 2014 and again on October 29, 2014. (Required Corrective Action)
3. Any further information regarding this matter will be communicated to the Bureau of Environmental Radiation Protection, NYS DOH [New York State Department of health]. (Required Corrective Action)"

New York State Event Report Number: NY-14-05

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf