Consolidated Line Item Improvement Process (CLIIP)
The purpose of the CLIIP is to streamline the license amendment review
process involving TSTF changes applicable to multiple plants. By using
a standardized process such as the CLIIP, the burden on an individual
licensee would be reduced by saving resources in preparing license amendment
applications and, at the same time, the NRC staff review process would
become more efficient. Each amendment application made as part of the
CLIIP will be processed and noticed int he Federal Register in accordance
with applicable rules and NRC Procedures, the CLIIP is further described
in the Regulatory Issue Summary 2000-06
.
The following TSTFs have been approved and are available for adoption by Licensees for their
specific plant TS. All TSTFs that were made available for adoption under CLIIP after February
2006 have Model SEs and Model Applications posted in the
Federal Register
.
Some of the links on this page are to non-NRC servers and websites and are provided solely as a reference for the convenience of users. NRC cannot guarantee the authenticity of documents or the validity of information obtained at these non-NRC websites. See our Site Disclaimer for more information.
This page includes links to files in non-HTML format. See Plugins, Viewers, and Other Tools for more information.
| Approved TSTF Traveler | Title and ADAMS Notice of Availability (NOA), Model Application, Model SE, Other Models if Available | Applicability -Based on Nuclear Supply System Vendor (Reactor Type) | CLIIP Notice of Availability (NOA) from
Federal Register |
|---|---|---|---|
| N/A | Elimination of Typical License Condition Requiring Reporting of Violations of Section 2.C of Operating License
ML053010227
Example Application ML053070370 Previous Notice for Comment (including model SE) ML052350500 |
All plant designs | 70 Fed. Reg. 67202
(Nov. 4, 2005) [TEXT] [PDF] |
| *358, R6 ML012690219 | Missed Surveillance Requirements ML012670082 Example application ML012670082 |
All plant designs | 66 Fed. Reg. 49714
(Sept. 28, 2001) [TEXT] [PDF] |
| **359, R9 ML031190607 |
Increase Flexibility in MODE Restraints ML030900056 Example application ML030900056 |
All plant designs | 68 Fed. Reg. 16579
(April 4,2003) [TEXT] [PDF] |
| 366 ML003734003 |
Elimination of Requirements for a Post Accident Sampling System (PASS) ML003750475 Example application ML003754812 |
Westinghouse and Combustion Engineering Designs | 65 Fed. Reg. 65018
(Oct 31, 2000) [TEXT] [PDF] |
| 369, R1 ML040050211 |
Removal of Monthly Operating report and Occupational Radiation Exposure Report
ML041690439
Example Application ML041800481 |
All plant designs | 69 Fed. Reg. 35067
(June 23, 2004) [TEXT] [PDF] |
| 370 ML003771348 |
Increase Accumulator Completion Time
ML030640760
Example application ML030640794 |
Westinghouse | 68 Fed. Reg. 11880
(March 12, 2003) [TEXT] [PDF] |
| 372, R4 ML041200567 | Addition of LCO 3.0.8 on the Inoperability of Snubbers
ML051160013
Example Application to adopt TSTF-372 ML051160013 |
All plant designs | 70 Fed. Reg. 23252
(April 4,2005) [TEXT] [PDF] |
| 373, R2 ML022460403 |
Extending the Completion Time for Inoperable Containment Isolation Valves
ML040490239 Example application ML040490270 |
Combustion Engineering | 69 Fed. Reg. 7986
(Feb. 20, 2004) [TEXT] [PDF] |
| 374, R0 ML011340449 |
Revision to TS 5.5.13 and Associated TS Bases for Diesel Fuel Oil ML071010061 Model safety evaluation (SE) 71 Fed. Reg. 9179 Model no significant hazards consideration (NSHC) determination. 71 Fed. Reg. 9179 Example Application ML071010061 |
All | 71 Fed. Reg. 20735
(April 21, 2006) [TEXT] [PDF] |
| 404 ML011630155 |
Scram Discharge Volume Vent and Drain Valves ML030980809 Example application ML030980665 |
Boiling Water Reactors | 68 Fed. Reg. 18294
(April 15, 2003) [TEXT] [PDF] |
| 409, R2 ML033280006 | Containment Spray System completion Time Extension (CE NPSD-1045-A) ML062930127 |
Combustion Engineering | 71 Fed. Reg. 65148
(Nov. 7, 2006) [TEXT] [PDF] |
| 412, R3 ML070100363 |
Provide Actions for One Steam Supply to Turbine Drive AFW/EFW Pump Inoperable ML071230105 | Westinghouse | 72 Fed. Reg. 39089
(July 17, 2007) [TEXT] [PDF] |
| 413 ML011980194 |
Eliminate Post Accident Sampling Requirements for Boiling Water Reactors ML020780459
Example application ML003754812 |
Boiling Water Reactors | 67 Fed. Reg. 13027
(March 20, 2002) [TEXT] [PDF] |
| 421 ML013390280 |
Extending the Inspection Interval for Reactor Coolant Pump Flywheels ML032890138 Example application ML032890167 |
Westinghouse | 68 Fed. Reg. 60422
(Oct. 22, 2003) [TEXT] [PDF] |
| 422, R1
ML030270099 |
Risk-Informed Modification to Selected Action End States for CEOG PWR L051650153 Example Application to adopt TSTF-422 ML051650162 Previous Notice for Comment ML051170362 |
Combustion Engineering Plants | 70 Fed. Reg. 38729
(July 5, 2005) [TEXT] [PDF] |
| 423, R0 ML032270250 |
Risk-Inform
Requirements Regarding Selected Required Action End States ML060760206
Previous Notice for Comment (including model SE) ML051160056 |
Boiling Water Reactors | 71 Fed. Reg. 14726
(March 23, 2006) [TEXT] [PDF] |
| 427, R2 ML061240055 |
Allowance for Non Technical Specification Barrier Degradation on Supported System OPERABILITY ML062340423 | All plant designs | 71 Fed. Reg. 58444 (Oct. 3, 2006) [TEXT] [PDF] |
431, R3 ML093570241 |
Change in Technical Specifications End States (BAW-2441) ML102310381 Model Application ML102310365 Model Safety Evaluation ML102310365 |
Babcock & Wilcox | 75 FR 75705 (Dec. 6, 2010) [TEXT] [PDF] |
432, R1 ML103360003 |
Change in Technical Specifications End States (WCAP-16294) ML12072A169 Model Application ML113202614 Model Safety Evaluation ML120200384 |
Westinghouse | 77 FR 27814 (May 11, 2012) [TEXT] [PDF] |
| 442 ML021830167 |
Elimination of Post Accident Sampling Requirements for Babcock & Wilcox Co.
ML031270010 Example application ML031270010 |
Babcock & Wilcox Co. | 68 Fed. Reg. 25664
(May 13, 2003) [TEXT] [PDF] |
| 447, R1 ML032020007 |
Eliminate Hydrogen Recombiner Requirement, and Relax the Hydrogen and Oxygen Monitor Requirements
ML032600597 Example application ML032600597 |
All plant designs | 68 Fed. Reg. 55416
(Sept. 25, 2003) [TEXT] [PDF] |
| 448, R3 ML062210095 ML063630467 |
Control Room Habitability
ML063460558
Model application ML063460558 ML070330657 |
All plant designs | 72 Fed. Reg. 2022
(January 17, 2007) [TEXT] [PDF] |
| 449, R4
ML051090200 |
Steam Generator Tube Integrity ML051160106 Example Application to adopt TSTF-449 ML061040351 Previous Notice for Comment (Including Model SE) ML050310015 Simplified Model SE ML070300547 |
Pressurized Water Reactors | 70 Fed. Reg. 24126
(May 6, 2005) [TEXT] [PDF] |
| 454,R1 ML052700153 | Increase PCIV [Primary Containment Isolation Valves] Completion Times
ML053070451
Example Application ML053070410 |
Boiling Water Reactors | 70 Fed. Reg. 73802
(Dec. 13, 2005) [TEXT] [PDF] |
| 460 ML033350006 |
Control Rod Scram Time Testing Frequency ML042250224
Example Application ML061320010 |
Boiling Water Reactors | 69 Fed. Reg. 51864
(Aug. 23, 2004) [TEXT] [PDF] |
| 475, R1 ML071420428 |
Control Rod Notch Testing Frequency and SRM Insert Control Rod Action ML073050017 |
All plant designs | 72 Fed. Reg. 63935
(Nov. 13, 2007) [TEXT] [PDF] |
| 476, R1 ML070090561 |
Improved BPWS Control Rod Insertion Process (NEDO-33091) ML070880921 |
Boiling Water Reactors | 72 Fed. Reg. 29004 (May 23, 2007) [TEXT] [PDF] |
| 477, R3 ML062510321 |
Add Action for Two Inoperable Control Room AC Subsystems ML070510176 | Boiling Water Reactors | 72 Fed. Reg. 14143 (March 26, 2007) [TEXT] [PDF] |
| 478, R2 ML071920140 |
BWR Technical Specification Changes that Implement the Revised Rule for Combustible Gas Control ML073170138 |
Boiling Water Reactors | 72 Fed. Reg. 65610
(Nov. 21, 2007) [TEXT] [PDF] |
| 484 ML052930102 |
Use of TS 3.10.1 for Scram Time Testing Activities ML062760109
Example Application ML062990425 |
Boiling Water Reactors | Model SE 71 Fed. Reg. 63050 (Oct. 27, 2006) [TEXT] [PDF] Model Application 71 Fed. Reg. 68642 (Nov. 27, 2006) [TEXT] [PDF] |
| 486, R2 ML071300267 |
Revise MTC Surveillance for Startup Test Activity Reduction (STAR) Program (WCAP-16011) ML072400538 |
Westinghouse | 72 Fed. Reg. 51259 (Sep. 6, 2007) [TEXT] [PDF] |
| 487, R1 ML071240259 |
Relocate DNB Parameters to the COLR ML071230184 |
Westinghouse | 72 Fed. Reg. 31108 (June 5, 2007) [TEXT] [PDF] |
| 490,R0 ML052630462 |
Deletion of E Bar definition and revision to RCS specific activity
ML070250176 Example Application ML070250176 |
Pressurized Water Reactors | 72 Fed. Reg. 12217 (March 15, 2007) [TEXT] [PDF] |
| 491,R2 ML061500078 |
Removal of Main Steam and Main Feedwater Valve Isolation Times from TECHNICAL SPECIFICATIONS ML063390370 Example Application ML063390370 |
Pressurized Water Reactors | Model SE 71 Fed. Reg. 58884 (Oct. 5, 2006) [TEXT] [PDF] Model Application 71 Fed. Reg. 78472 (Dec. 29, 2006) [TEXT] [PDF] |
510, R2 |
Revision to Steam Generator Program Inspection Frequencies and Tube Sample Selection ML112101604 Model Application ML102850215 Model Safety Evaluation ML112101513 |
Pressurized Water Reactors |
Vol 76 FR 66763 (Oct. 27, 2011) [TEXT] [PDF] |
511, R0 |
Eliminate Working Hour Restrictions from TS 5.2.2 to Support Compliance with 10 CFR Part 26 ML083180519 | All plant designs |
Vol 73 FR 79923 (Dec. 30, 2008) [TEXT] [PDF] |
| 513, R3 ML102360355 |
Revise PWR Operability Requirements and Actions for RCS Leakage Information ML101340267 | Pressurized Water Reactors | Vol 76 FR 189 [TEXT] [PDF] |
| 514, R2 ML103280389 |
Revise BWR Operability Requirements and Actions for RCS Leakage Instrumentation ML102300733 | Boiling Water Reactors | Vol 75 FRN 79048 [TEXT] [PDF] |
| 535, R0 ML112200436 |
Revise Shutdown Margin Definition to Address Advanced Fuel Designs ML12355A767 Model Application ML112200436 Model Safety Evaluation ML12355A772 |
Boiling Water Reactors | 78 FR 13100 [TEXT] [PDF] |
* Equivalent to TSTF-358, R.5 as modified by staff review and comments, as discussed in FRN announcement CLIIP availability.
** Equivalent to TSTF-359, R.8 as modified by staff responses to public comments 8 and 20 in the FRN.