United States Nuclear Regulatory Commission - Protecting People and the Environment

River Bend 1

1Q/2012 Performance Indicators

Licensee's General Comments: none



Link to Notes

Unplanned Scrams per 7000 Critical Hrs 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
Unplanned scrams 0 0 0 0 0 0 1.0 0
Critical hours 2184.0 2111.5 2209.0 1508.6 2184.0 2208.0 2154.0 2183.0
                 
Indicator value 0.9 0 0 0 0 0 0.9 0.8


Licensee Comments: none




Link to Notes

Unplanned Power Changes per 7000 Critical Hrs 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
Unplanned power changes 0 0 1.0 0 1.0 0 0 0
Critical hours 2184.0 2111.5 2209.0 1508.6 2184.0 2208.0 2154.0 2183.0
                 
Indicator value 0.9 0.8 1.6 0.9 1.7 1.7 0.9 0.8

Licensee Comments: none






Link to Notes

Unplanned Scrams with Complications 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
Scrams with complications 0 0 0 0 0 0 1.0 0
                 
                 
Indicator value 0.0 0.0 0.0 0.0 0.0 0.0 1.0 1.0

Licensee Comments: none






Link to Notes

Safety System Functional Failures (BWR) 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
Safety System Functional Failures 0 1 0 1 0 0 0 0
                 
Indicator value 0 1 1 2 2 1 1 0

Licensee Comments: none






Link to Notes

Mitigating Systems Performance Index, Emergency AC Power System 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
UAI (ΔCDF) 1.10E-08 8.95E-09 2.43E-08 2.31E-08 1.85E-08 1.59E-08 1.53E-08 1.45E-08
URI (ΔCDF) 1.57E-07 1.22E-07 6.74E-08 6.63E-08 6.71E-08 6.78E-08 3.07E-07 3.08E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value 1.70E-07 1.30E-07 9.20E-08 8.90E-08 8.60E-08 8.40E-08 3.20E-07 3.20E-07

Licensee Comments:

4Q/11: Changed PRA Parameter(s).






Link to Notes

Mitigating Systems Performance Index, High Pressure Injection System 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
UAI (ΔCDF) 2.28E-09 2.28E-09 1.01E-08 9.64E-09 9.64E-09 9.37E-09 4.20E-09 5.81E-09
URI (ΔCDF) -2.96E-08 -2.94E-08 2.47E-08 2.41E-08 2.82E-08 2.77E-08 1.10E-09 1.21E-09
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -2.70E-08 -2.70E-08 3.50E-08 3.40E-08 3.80E-08 3.70E-08 5.30E-09 7.00E-09

Licensee Comments:

4Q/11: Changed PRA Parameter(s).

2Q/11: Changed PRA Parameter(s).

1Q/11: Changed PRA Parameter(s).

4Q/10: Changed PRA Parameter(s).

3Q/10: Changed PRA Parameter(s).

2Q/10: Changed PRA Parameter(s).






Link to Notes

Mitigating Systems Performance Index, Heat Removal System 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
UAI (ΔCDF) -2.16E-08 -2.16E-08 -1.35E-08 -1.39E-08 -1.32E-08 -1.09E-08 -4.23E-09 2.65E-09
URI (ΔCDF) -6.73E-08 -6.69E-08 1.07E-07 9.53E-08 9.17E-08 8.81E-08 2.78E-08 5.21E-08
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -8.90E-08 -8.90E-08 9.40E-08 8.10E-08 7.80E-08 7.70E-08 2.40E-08 5.50E-08

Licensee Comments:

4Q/11: Changed PRA Parameter(s).






Link to Notes

Mitigating Systems Performance Index, Residual Heat Removal System 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
UAI (ΔCDF) -2.25E-08 -2.25E-08 -3.47E-08 -3.47E-08 -3.47E-08 -3.47E-08 -5.07E-08 -3.95E-08
URI (ΔCDF) -7.84E-08 -7.74E-08 -7.69E-08 -7.57E-08 -7.50E-08 -7.37E-08 -1.25E-07 -1.28E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -1.00E-07 -1.00E-07 -1.10E-07 -1.10E-07 -1.10E-07 -1.10E-07 -1.80E-07 -1.70E-07

Licensee Comments:

4Q/11: Changed PRA Parameter(s).






Link to Notes

Mitigating Systems Performance Index, Cooling Water Systems 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
UAI (ΔCDF) -2.64E-09 -2.64E-09 -2.64E-09 -2.64E-09 -2.64E-09 -2.64E-09 -1.56E-09 -1.56E-09
URI (ΔCDF) -2.43E-08 -2.43E-08 -2.26E-08 3.41E-07 3.41E-07 3.41E-07 4.70E-07 4.70E-07
PLE NO NO NO NO NO NO NO NO
                 
Indicator value -2.70E-08 -2.70E-08 -2.50E-08 3.40E-07 3.40E-07 3.40E-07 4.70E-07 4.70E-07

Licensee Comments:

1Q/12: Risk Cap Invoked.

4Q/11: Changed PRA Parameter(s).

4Q/11: Risk Cap Invoked. Changed PRA Parameter(s).

4Q/11: Risk Cap Invoked.






Link to Notes

Reactor Coolant System Activity 4/10 5/10 6/10 7/10 8/10 9/10 10/10 11/10 12/10 1/11 2/11 3/11
Maximum activity 0.000866 0.001880 0.001670 0.001640 0.001670 0.001540 0.001380 0.001520 0.001530 0.001400 0.000626 0.000658
Technical specification limit 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
                         
Indicator value 0.4 0.9 0.8 0.8 0.8 0.8 0.7 0.8 0.8 0.7 0.3 0.3
Reactor Coolant System Activity 4/11 5/11 6/11 7/11 8/11 9/11 10/11 11/11 12/11 1/12 2/12 3/12
Maximum activity 0.000583 0.000604 0.000572 0.000659 0.000491 0.000497 0.000500 0.000516 0.000658 0.000701 0.000534 0.000610
Technical specification limit 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2
                         
Indicator value 0.3 0.3 0.3 0.3 0.2 0.2 0.3 0.3 0.3 0.4 0.3 0.3

Licensee Comments: none






Link to Notes

Reactor Coolant System Leakage 4/10 5/10 6/10 7/10 8/10 9/10 10/10 11/10 12/10 1/11 2/11 3/11
Maximum leakage 2.290 2.330 2.590 2.510 2.920 2.360 2.270 2.540 2.330 2.370 2.250 2.210
Technical specification limit 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0
                         
Indicator value 7.6 7.8 8.6 8.4 9.7 7.9 7.6 8.5 7.8 7.9 7.5 7.4
Reactor Coolant System Leakage 4/11 5/11 6/11 7/11 8/11 9/11 10/11 11/11 12/11 1/12 2/12 3/12
Maximum leakage 2.100 2.290 2.080 2.080 2.080 2.110 2.940 2.090 2.340 2.090 2.120 2.550
Technical specification limit 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0
                         
Indicator value 7.0 7.6 6.9 6.9 6.9 7.0 9.8 7.0 7.8 7.0 7.1 8.5

Licensee Comments: none






Link to Notes

Drill/Exercise Performance 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
Successful opportunities 54.0 43.0 10.0 24.0 33.0 98.0 30.0 46.0
Total opportunities 56.0 43.0 10.0 24.0 34.0 101.0 30.0 48.0
                 
Indicator value 97.9% 98.0% 97.8% 97.7% 97.3% 97.3% 97.6% 97.7%

Licensee Comments: none






Link to Notes

ERO Drill Participation 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
Participating Key personnel 128.0 132.0 95.0 96.0 95.0 97.0 91.0 92.0
Total Key personnel 128.0 132.0 95.0 96.0 95.0 97.0 91.0 92.0
                 
Indicator value 100.0% 100.0% 100.0% 100.0% 100.0% 100.0% 100.0% 100.0%

Licensee Comments: none






Link to Notes

Alert & Notification System 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
Successful siren-tests 1184 1201 1209 1207 1207 1207 1116 1201
Total sirens-tests 1209 1209 1209 1209 1209 1209 1116 1209
                 
Indicator value 98.6% 98.7% 99.0% 99.3% 99.8% 99.9% 99.9% 99.7%

Licensee Comments: none






Link to Notes

Occupational Exposure Control Effectiveness 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
High radiation area occurrences 0 0 0 1 0 0 0 0
Very high radiation area occurrences 0 0 0 0 0 0 0 0
Unintended exposure occurrences 0 0 0 0 0 0 0 0
Indicator value 0 0 0 1 1 1 1 0

Licensee Comments: none






Link to Notes

RETS/ODCM Radiological Effluent 2Q/10 3Q/10 4Q/10 1Q/11 2Q/11 3Q/11 4Q/11 1Q/12
RETS/ODCM occurrences 0 0 0 0 0 0 0 0
                 
Indicator value 0 0 0 0 0 0 0 0

Licensee Comments: none